Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI
Skeletal Radiology · 2026-07 · 55 (7) · 1663-1672
DOI: 10.1007/s00256-026-05215-1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Skeletal Radiology, online erschienen am 13.04.2026. Verfasst von Soung Mo Kang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-Gil, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 13620, Republic …. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lumbar Vertebrae, Patient Positioning, Pressure Ulcer. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Seoul National University Bundang Hospital.
Themen: Dekubitus
Abstract (Originalsprache)
OBJECTIVE: To evaluate image quality of decubitus lumbar spine MRI using a flexible coil with or without Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) sequence compared to that of the conventional supine lumbar spine MRI. MATERIALS AND METHODS: This study was conducted on patients who underwent decubitus lumbar spine MRI applying a flexible coil at a single center between February 1 and March 11, 2025, and had a Numeric Rating Scale (NRS) pain score ≥ 5, while examining supine MRI. Signal-to-noise ratio (SNR) in T2-weighted fast-spin-echo (FSE) sequence for supine, decubitus, and PROPELLER sequence at decubitus position were measured and compared using the Wilcoxon signed-rank test. Two radiologists independently evaluated the subjective image quality of each spine MRI. RESULTS: A total of 35 patients (mean age, 66 ± 13 years) were included in our study. On T2-weighted sagittal images, cerebrospinal fluid (CSF) SNR was highest in the supineFSE (589.3, 95% CI: 482.1-695.1) and significantly lower in both decubitusFSE (431.2, 95% CI: 365.9-479.9) and decubitusPROPELLER (417.8, 95% CI: 389.2-439.1) (p < 0.001). On T2-weighted axial images, SNRCSF values of supineFSE (284.6, 95% CI: 256.4-331.0) and decubitusPROPELLER (245.0, 95% CI: 215.7-336.1) were both statistically higher than that of decubitusFSE (176.1, 95% CI: 135.9-209.2) (p < 0.001). In qualitative analysis, there was no statistical difference across supineFSE, decubitusFSE, and decubitusPROPELLER. CONCLUSION: Image quality of decubitus lumbar spine MRI using a flexible coil was clinically feasible with acceptable image quality. PROPELLER sequence improved SNRCSF on axial images in decubitus position.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-Gil, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 13620, Republic of Korea.
- Department of Radiology, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-Gil, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 13620, Republic of Korea. mdccg82@gmail.com.
- Department of Radiology, College of Medicine, Seoul National University, 103, Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
Förderung
- Seoul National University Bundang Hospital
Zitieren
APA
Kang, S. M., Do, Y., Chee, C. G., Kim, Y., Lee, E., Kim, Y. J., & Lee, J. W. (2026). Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI. Skeletal Radiology, 55(7), 1663-1672. https://doi.org/10.1007/s00256-026-05215-1
Vancouver
Kang SM, Do Y, Chee CG, Kim Y, Lee E, Kim YJ, et al. Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI. Skeletal Radiology. 2026;55(7):1663-1672. doi:10.1007/s00256-026-05215-1
BibTeX
@article{Kang2026,
author = {Kang, Soung Mo and Do, Yoonah and Chee, Choong Guen and Kim, Youngjune and Lee, Eugene and Kim, Yeo Ju and Lee, Joon Woo},
title = {Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI},
journal = {Skeletal Radiology},
year = {2026},
volume = {55},
number = {7},
pages = {1663--1672},
doi = {10.1007/s00256-026-05215-1}
}
EUVIMED