A Predictive Bioengineering Model of Dental Implant Instability in Systemic Bone Disorders: A Periotest-Based Analysis
Bioengineering · 03.03.2026 · 13 (3) · 297
DOI: 10.3390/bioengineering13030297 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 03.03.2026. Verfasst von Liliana Sachelarie und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Medicine, Apollonia University, 700511 Iasi, Romania. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
(1)
Background
Dental implant instability represents a dynamic biomechanical process influenced by functional loading, peri-implant bone stiffness, and systemic conditions affecting bone metabolism. In patients with systemic bone disorders, altered material properties and impaired remodeling may reduce effective implant–bone interface stiffness, potentially increasing micromotion beyond what is detectable by conventional clinical indicators. The aim of this study was to develop and evaluate a predictive bioengineering model of implant instability based on Periotest-derived dynamic measurements. (2)
Methods
A retrospective analysis was performed on 79 dental implants placed in patients with and without systemic bone disorders. Implant micromotion was quantified using Periotest values (PTVs). Linear and logistic regression analyses were applied to model the relationship between systemic bone status, implant location, and biomechanical instability (defined as PTV > +2.0). A load–stiffness–micromotion framework was used to provide mechanical interpretation of the findings. (3)
Results
Implants placed in patients with systemic bone disorders exhibited significantly higher Periotest values compared to controls (+2.1 ± 1.3 vs. −0.4 ± 1.1; mean difference 2.5 PTV units, 95% CI 1.97–3.04; p < 0.001). High-risk biomechanical instability (PTV > +2.0) was observed in 46% of implants in the systemic group compared to 9% in controls. Multivariable logistic regression demonstrated that systemic bone disorders were independently associated with a 2.6-fold increase in the odds of high-risk instability after adjustment for implant location. The observed instability pattern was consistent with reduced effective peri-implant stiffness in systemically compromised bone. (4)
Conclusions
Dental implant instability in systemically compromised patients can be interpreted as a load–stiffness imbalance at the implant–bone interface. The proposed predictive bioengineering framework links dynamic Periotest measurements with mechanical modeling and systemic bone status, enabling quantitative risk stratification beyond static stability assessments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dental Medicine, Apollonia University, 700511 Iasi, Romania.
- Department of Dental Medicine, Dimitrie Cantemir University, 540545 Târgu Mureș, Romania.
- Faculty of Medicine and Pharmacy, University Ovidius, Constanta, Mamaia Boulevard, 900527 Constanta, Romania.
- Private Dental Practice, 900162 Constanta, Romania.
- Faculty of Medicine, Grigore T. Popa University of Medicine and Pharmacy Iasi, University Street 16, 700115 Iasi, Romania.
ORCID-Profile: Liliana Sachelarie, Ramona Feier, Corina-Laura Ștefănescu, Loredana Liliana Hurjui
Zitieren
APA
Sachelarie, L., Feier, R., Ștefănescu, C. L., Grigorian, M., Murineanu, R. M., Agripina, Z., & Hurjui, L. L. (2026). A Predictive Bioengineering Model of Dental Implant Instability in Systemic Bone Disorders: A Periotest-Based Analysis. Bioengineering, 13(3), 297. https://doi.org/10.3390/bioengineering13030297
Vancouver
Sachelarie L, Feier R, Ștefănescu CL, Grigorian M, Murineanu RM, Agripina Z, et al. A Predictive Bioengineering Model of Dental Implant Instability in Systemic Bone Disorders: A Periotest-Based Analysis. Bioengineering. 2026;13(3):297. doi:10.3390/bioengineering13030297
BibTeX
@article{Sachelarie2026,
author = {Sachelarie, Liliana and Feier, Ramona and Ștefănescu, Corina-Laura and Grigorian, Mircea and Murineanu, Rodica-Maria and Agripina, Zaharia and Hurjui, Loredana Liliana},
title = {A Predictive Bioengineering Model of Dental Implant Instability in Systemic Bone Disorders: A Periotest-Based Analysis},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {3},
pages = {297},
doi = {10.3390/bioengineering13030297}
}
EUVIMED