EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Cumulative Error in Digital Workflows for Full-Arch Implant Rehabilitation: A Narrative Review

Hao-Ting Chen iD, Sheng-Wei Feng iD, Thi Thuy Tien Vo, Yung-Li Wang iD, Fang-Yu Fan iD, I-Ta Lee iD

Bioengineering · 13.02.2026 · 13 (2) · 219

DOI: 10.3390/bioengineering13020219 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Bioengineering, online erschienen am 13.02.2026. Verfasst von Hao-Ting Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite the widespread adoption of digital technologies in modern implant dentistry, a comprehensive synthesis of error propagation across the entire workflow of full-arch implant rehabilitation remains absent. This narrative review aimed to synthesize current evidence on cumulative error propagation throughout the digital workflow of full-arch implant rehabilitation. Rather than focusing on isolated accuracy metrics, this article proposes a conceptual “Error Control Framework” to elucidate how minor deviations introduced at different workflow stages interact and amplify. A comprehensive literature search (2015–2025) was conducted to analyze error generation across five interrelated phases: Planning, Acquisition, Processing, Output, and Feedback. The evidence indicates that inaccuracies in full-arch implant rehabilitation behave as a cascading system (snowball effect) rather than isolated events. Errors introduced during early stages establish an irreversible baseline that is magnified during digital processing and manufacturing. Consequently, reactive verification at delivery alone is insufficient. To address this, this article proposes a proactive Error Control Framework that integrates a “Front-End Loading” strategy (necessitating strict upstream standardization of scanning strategies and scan-body geometry), alongside “Critical Control Points” (enforcing mandatory physical verification prior to final manufacturing). Viewing digital full-arch rehabilitation as a cumulative error system allows clinicians to implement preventive strategies and verification checkpoints, improving passive fit and long-term mechanical and biological outcomes.

Schlagwörter

Stichwörter der Autor:innen

computer-aided designcomputer-aided manufacturingdental implantsdental prosthesisimplant-supportedworkflow

Autor:innen und Institutionen

  • School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Faculty of Dentistry, Nguyen Tat Thanh University, Ho Chi Minh City 700000, Vietnam.
  • School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan.

ORCID-Profile: Hao-Ting Chen, Sheng-Wei Feng, Yung-Li Wang, Fang-Yu Fan, I-Ta Lee

Förderung

  • National Science and Technology Council, Taiwan

Zitieren

APA

Chen, H. T., Feng, S. W., Vo, T. T. T., Wang, Y. L., Fan, F. Y., & Lee, I. T. (2026). Cumulative Error in Digital Workflows for Full-Arch Implant Rehabilitation: A Narrative Review. Bioengineering, 13(2), 219. https://doi.org/10.3390/bioengineering13020219

Vancouver

Chen HT, Feng SW, Vo TTT, Wang YL, Fan FY, Lee IT. Cumulative Error in Digital Workflows for Full-Arch Implant Rehabilitation: A Narrative Review. Bioengineering. 2026;13(2):219. doi:10.3390/bioengineering13020219

BibTeX
@article{Chen2026,
  author = {Chen, Hao-Ting and Feng, Sheng-Wei and Vo, Thi Thuy Tien and Wang, Yung-Li and Fan, Fang-Yu and Lee, I-Ta},
  title = {Cumulative Error in Digital Workflows for Full-Arch Implant Rehabilitation: A Narrative Review},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {2},
  pages = {219},
  doi = {10.3390/bioengineering13020219}
}
Kostenlos starten →