Übersichtsarbeit in der Zeitschrift Australian Dental Journal, online erschienen am 25.11.2025. Verfasst von Aaron Wai Harng Wong und 2 weiteren Autor:innen. Beteiligte Einrichtung: University of Western Australia, Crawley, Western Australia, Australia. Hauptthemen laut MEDLINE: Workflow, Dental Implants, Dental Impression Technique, Dental Prosthesis Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Misfit at the implant–prosthesis interface arises from small errors that occur during impression‐taking, cast fabrication and milling. Implant verification jigs (IVJs) have been described as a quality‐control device in fixed implant prosthodontics, yet protocols and indications are inconsistently described This narrative review aims to compare materials and fabrication methods, map their functional roles and provide clinical recommendations for both analogue and digital workflows.
Methods
Peer‐reviewed English‐language publications from 1 January 1980 to 30 October 2025 were searched on PubMed and Scopus using MeSH and free‐text terms for dental implants and IVJs. Eligible studies include technique reports, in vitro studies, clinical studies and narrative reviews that reported materials, fabrication or functional roles of IVJs in fixed implant prosthodontics. Titles, abstracts and full texts were screened against predefined criteria. Data were synthesised narratively by workflow and verification approach.
Results
Fifty‐two publications met the criteria (29 technique descriptions, 12 in vitro, 8 in vivo, 1 case report, 2 reviews). The materials reported for IVJs included PMMA, UDMA, photopolymerising composite resins and Type III/IV dental stone jigs. In analogue workflows, intra‐oral and extra‐oral verification procedures have been reported. In digital workflows, digitising IVJs or implant verification casts as well as CAD‐CAM IVJs have been described.
Conclusions
Within the limits of this narrative review, IVJs can be used as adjuncts for conventional impressions and intra‐oral scans with vertical scanbodies. Photogrammetry and systems that pair horizontal scanbodies and AI‐based recognition provide datasets with greater accuracy, negating the need for conventional IVJs. Future studies should standardise verification strategies and evaluate long‐term clinical outcomes. Clinical Relevance This narrative review clarifies the indications for IVJs, outlines workable analogue and digital strategies, and provides clinical recommendations. Selective use of IVJs prior to the fabrication of the definitive prosthesis can reduce the likelihood of misfit.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of Western Australia, Crawley, Western Australia, Australia.
ORCID-Profile: Aaron Wai Harng Wong, Adam Hamilton
Zitieren
APA
Wong, A. W. H., Nedelcu, R., & Hamilton, A. (2025). Clinical Recommendations for Implant Verification Jigs in Analogue and Digital Workflows. A Narrative Review. Australian Dental Journal, 70(S1). https://doi.org/10.1111/adj.70025
Vancouver
Wong AWH, Nedelcu R, Hamilton A. Clinical Recommendations for Implant Verification Jigs in Analogue and Digital Workflows. A Narrative Review. Australian Dental Journal. 2025;70(S1). doi:10.1111/adj.70025
BibTeX
@article{Wong2025,
author = {Wong, Aaron Wai Harng and Nedelcu, Robert and Hamilton, Adam},
title = {Clinical Recommendations for Implant Verification Jigs in Analogue and Digital Workflows. A Narrative Review},
journal = {Australian Dental Journal},
year = {2025},
volume = {70},
number = {S1},
doi = {10.1111/adj.70025}
}
EUVIMED