Experimental Setup for the Validation of Photoplethysmography Devices for the Evaluation of Arteriovenous Fistulas

Simone Chiorboli, Adriano Brugnoli, Vincenzo Piemonte iD

Bioengineering · 18.09.2025 · 12 (9) · 990

DOI: 10.3390/bioengineering12090990 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 18.09.2025. Verfasst von Simone Chiorboli und 2 weiteren Autor:innen. Beteiligte Einrichtung: Unit of Chemical-Physics Fundamentals in Chemical Engineering, Department of Engineering, University Campus Bio-Medico of Rome, Via Álvaro del Portil…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study describes the design and validation of an experimental setup for testing photoplethysmographic (PPG) devices intended for the non-invasive monitoring of vascular accesses in hemodialysis patients. Continuous assessment of arteriovenous fistulas is essential to detect pathological conditions such as stenosis, which can compromise patient safety and dialysis efficacy. While PPG-based sensors are capable of detecting such anomalies, their clinical applicability must be supported by controlled in vitro validation. The developed system replicates the anatomical, mechanical, optical, and hemodynamic features of vascular accesses. A 3D fistula model was designed and fabricated via 3D printing and silicone casting. The hydraulic circuit used red India ink and a PWM-controlled pump to simulate physiological blood flow, including stenotic conditions. Quantitative validation confirmed anatomical accuracy within 0.1 mm tolerance. The phantom exhibited an average Shore A hardness of 20.3 ± 1.1, a Young’s modulus of 10.4 ± 0.9 MPa, and a compression modulus of 105 MPa—values consistent with soft tissue behavior. Burst pressure exceeded 2000 mmHg, meeting ISO 7198:2016 standards. Flow rates (400–700 mL/min) showed

Schlagwörter

Stichwörter der Autor:innen

arteriovenous fistulahemodialysisphantomsphotoplethysmographystenosisvascular access

Autor:innen und Institutionen

  • Unit of Chemical-Physics Fundamentals in Chemical Engineering, Department of Engineering, University Campus Bio-Medico of Rome, Via Álvaro del Portillo, 21, 00128 Roma, Italy.

ORCID-Profile: Vincenzo Piemonte

Zitieren

APA

Chiorboli, S., Brugnoli, A., & Piemonte, V. (2025). Experimental Setup for the Validation of Photoplethysmography Devices for the Evaluation of Arteriovenous Fistulas. Bioengineering, 12(9), 990. https://doi.org/10.3390/bioengineering12090990

Vancouver

Chiorboli S, Brugnoli A, Piemonte V. Experimental Setup for the Validation of Photoplethysmography Devices for the Evaluation of Arteriovenous Fistulas. Bioengineering. 2025;12(9):990. doi:10.3390/bioengineering12090990

BibTeX
@article{Chiorboli2025,
  author = {Chiorboli, Simone and Brugnoli, Adriano and Piemonte, Vincenzo},
  title = {Experimental Setup for the Validation of Photoplethysmography Devices for the Evaluation of Arteriovenous Fistulas},
  journal = {Bioengineering},
  year = {2025},
  volume = {12},
  number = {9},
  pages = {990},
  doi = {10.3390/bioengineering12090990}
}