A Self-Expanding Nitinol Fixation System for Atrial Leadless Pacemakers: Biomechanical Design and Evaluation
Bioengineering · 12.05.2025 · 12 (5) · 512
DOI: 10.3390/bioengineering12050512 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 12.05.2025. Verfasst von Yu-Tzu Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Electro-Mechanical Engineering, TamKang University, New Taipei City 251, Taiwan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
Atrial leadless pacemakers (ALPMs) offer a minimally invasive solution for patients requiring atrial pacing, but current designs face significant challenges related to fixation stability, perforation risk, and retrievability. This study presents a novel self-expanding nitinol fixation system designed for deployment within the left atrial appendage (LAA), incorporating a flexible adapter for secure pacemaker engagement and retrieval. Finite-element simulations were conducted to assess gravitational displacement across different anatomical orientations, and fixture-expansion behavior was analyzed under various mesh configurations. The pacemaker drop analysis results demonstrated minimal displacement in neutral and upward-tilted LAA models, with increased instability observed in downward-tilted orientations. The fixture-expansion study showed that the 0.2 mm mesh design provided adequate mechanical strength and strain tolerance while maintaining a compact profile. This novel fixation system improves current ALPM limitations by providing stable, retrievable anchoring and favorable biomechanical performance. It may also serve as a dual-function platform for atrial pacing and stroke prevention when integrated with a left atrial appendage (LAA) occluder. These findings support further preclinical validation for clinical translation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical and Electro-Mechanical Engineering, TamKang University, New Taipei City 251, Taiwan.
- Department of Cardiology, Chang Gung Memorial Hospital, Chiayi 613, Taiwan.
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.
- National Center for Instrumentation Research, National Institutes of Applied Research, Hsinchu 302, Taiwan.
- Division of Cardiology, Chang Gung Memorial Hospital, Linkou, Taoyuan 333, Taiwan.
- Institute of Pioneer Semiconductor Innovation, Industry Academia Innovation School, National Yang Ming Chiao Tung University, Hsinchu City 302, Taiwan.
ORCID-Profile: Yu-Sheng Lin, Lung-Sheng Wu, Pao-Hsien Chu
Förderung
- National Science and Technology Council
Zitieren
APA
Wang, Y. T., Lin, Y. S., Lin, Y. W., Chang, C. M., Wu, L. S., Lai, C. S., & Chu, P. H. (2025). A Self-Expanding Nitinol Fixation System for Atrial Leadless Pacemakers: Biomechanical Design and Evaluation. Bioengineering, 12(5), 512. https://doi.org/10.3390/bioengineering12050512
Vancouver
Wang YT, Lin YS, Lin YW, Chang CM, Wu LS, Lai CS, et al. A Self-Expanding Nitinol Fixation System for Atrial Leadless Pacemakers: Biomechanical Design and Evaluation. Bioengineering. 2025;12(5):512. doi:10.3390/bioengineering12050512
BibTeX
@article{Wang2025,
author = {Wang, Yu-Tzu and Lin, Yu-Sheng and Lin, Yu-Wei and Chang, Chun-Ming and Wu, Lung-Sheng and Lai, Chao-Sung and Chu, Pao-Hsien},
title = {A Self-Expanding Nitinol Fixation System for Atrial Leadless Pacemakers: Biomechanical Design and Evaluation},
journal = {Bioengineering},
year = {2025},
volume = {12},
number = {5},
pages = {512},
doi = {10.3390/bioengineering12050512}
}
EUVIMED