EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Incidence of Pacing‐Induced Cardiomyopathy in Active‐Fixation Leadless Pacemakers

Christopher Kopreski, Kevin John, Jingwen Huang, Ahmadreza Karimianpour, Thomas Deering, Antonio Sotolongo, Michael Hoosien, Mikhael El‐Chami, Ashish Bhimani, Kent R. Nilsson

Journal of Cardiovascular Electrophysiology · 17.11.2026

DOI: 10.1111/jce.70567 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 17.11.2026. Verfasst von Christopher Kopreski und 9 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Pacing‐induced cardiomyopathy (PICM) is a known complication of high right ventricular (RV) pacing burden with transvenous pacemakers, but its incidence with active‐fixation leadless pacemakers (LPs) is unknown. This study's aim was to determine the incidence of PICM among patients implanted with LPs using helix‐based active fixation and assess its association with heart failure hospitalizations (HFH). Methods and Results This multi‐center retrospective cohort study included patients implanted with active‐fixation LPs between 2021 and 2025. Left ventricular ejection fraction (LVEF) measurements were obtained pre‐ and post‐implant. Inclusion criteria were: de novo pacemaker implant, ≥ 20% RV pacing burden, baseline LVEF of > 50%, and > 30 days of follow‐up. PICM was defined as a ≥ 10% reduction in LVEF from baseline to a value < 50%, with no other identifiable causes for left ventricular dysfunction. Patient demographics, comorbidities, procedural history, and baseline pacemaker, electrocardiographic, and echocardiographic data were compared between patients with and without PICM. Categorical variables were analyzed using the “N–1” Chi‐squared or Fisher's exact test and continuous variables with Welch's t ‐test. Cox proportional hazards models were used for univariate analysis of PICM and HFH. Among 164 patients implanted with active‐fixation LPs, 57 met inclusion criteria (mean age 78 ± 11 years). Dual‐chamber systems accounted for 47.4% of implants, and 96.5% of ventricular devices were placed in the low RV septum. Six patients (10.5%) developed PICM during 14.2 ± 10.9 months of follow‐up, with a mean time to onset of 7.5 ± 2.4 months. Baseline characteristics did not differ significantly between patients with and without PICM. At the time of diagnosis, those with PICM had a greater decline in LVEF (23% vs. 2%, p < 0.001). Although RV pacing burden was higher in PICM patients (88.8% vs. 76.6%), this difference was not statistically significant. PICM was a strong predictor of HFH (HR: 6.9, p = 0.007).

Conclusion

PICM occurred in 10.5% of patients receiving active‐fixation LPs with high ventricular pacing burden. Our findings highlight the importance of standardized follow‐up echocardiography within the first year post‐implant to improve surveillance and timely recognition of PICM.

Zitieren

APA

Kopreski, C., John, K., Huang, J., Karimianpour, A., Deering, T., Sotolongo, A., Hoosien, M., El‐Chami, M., Bhimani, A., & Nilsson, K. R. (2026). Incidence of Pacing‐Induced Cardiomyopathy in Active‐Fixation Leadless Pacemakers. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70567

Vancouver

Kopreski C, John K, Huang J, Karimianpour A, Deering T, Sotolongo A, et al. Incidence of Pacing‐Induced Cardiomyopathy in Active‐Fixation Leadless Pacemakers. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70567

BibTeX
@article{Kopreski2026,
  author = {Kopreski, Christopher and John, Kevin and Huang, Jingwen and Karimianpour, Ahmadreza and Deering, Thomas and Sotolongo, Antonio and Hoosien, Michael and El‐Chami, Mikhael and Bhimani, Ashish and Nilsson, Kent R.},
  title = {Incidence of Pacing‐Induced Cardiomyopathy in Active‐Fixation Leadless Pacemakers},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70567}
}
Kostenlos starten →