Development and Metrological Characterization of Low-Cost Wearable Pulse Oximeter
Bioengineering · 19.03.2025 · 12 (3) · 314
DOI: 10.3390/bioengineering12030314 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 19.03.2025. Verfasst von Andrea Cataldo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PRIN Project "PRIN 2022 "CPMS - Reshaping the 255 Role of Measurement in the 4.0 Era: towards a Cyber-Physical Measurement System for Advanced 256 Monitoring A…, PRIN Project “PRIN 2022”.
Abstract (Originalsprache)
Pulse oximetry is essential for monitoring arterial oxygen saturation (SpO2) and heart rate (HR) in various medical scenarios. However, the traditional pulse oximeters face challenges related to high costs, motion artifacts, and susceptibility to ambient light interference. This work presents a low-cost experimental pulse oximeter prototype designed to address these limitations through design advancements. The device incorporates a 3D-printed finger support to minimize motion artifacts and excessive capillary pressure, along with an elastic element to enhance stability. Unlike conventional transmission-based oximetry, the prototype employs a reflectance-based measurement approach, improving versatility and enabling reliable readings even in cases of poor peripheral perfusion. Additionally, the integration of light-shielding materials mitigates the effects of ambient illumination, ensuring accurate operation in challenging environments such as surgical settings. Metrological characterization demonstrates that the prototype achieves accuracy comparable to that of the commercial GIMA Oxy-50 pulse oximeter while maintaining a production cost at approximately one-tenth of the commercial alternatives. This study highlights the potential of the prototype to deliver affordable and reliable pulse oximetry for different applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy.
ORCID-Profile: Andrea Cataldo, Antonio Masciullo, Raissa Schiavoni
Förderung
- PRIN Project "PRIN 2022 "CPMS - Reshaping the 255 Role of Measurement in the 4.0 Era: towards a Cyber-Physical Measurement System for Advanced 256 Monitoring A…
- PRIN Project “PRIN 2022”
Zitieren
APA
Cataldo, A., Cataldo, E., Masciullo, A., & Schiavoni, R. (2025). Development and Metrological Characterization of Low-Cost Wearable Pulse Oximeter. Bioengineering, 12(3), 314. https://doi.org/10.3390/bioengineering12030314
Vancouver
Cataldo A, Cataldo E, Masciullo A, Schiavoni R. Development and Metrological Characterization of Low-Cost Wearable Pulse Oximeter. Bioengineering. 2025;12(3):314. doi:10.3390/bioengineering12030314
BibTeX
@article{Cataldo2025,
author = {Cataldo, Andrea and Cataldo, Enrico and Masciullo, Antonio and Schiavoni, Raissa},
title = {Development and Metrological Characterization of Low-Cost Wearable Pulse Oximeter},
journal = {Bioengineering},
year = {2025},
volume = {12},
number = {3},
pages = {314},
doi = {10.3390/bioengineering12030314}
}
EUVIMED