MW-FlexNIRS: wearable, low-cost, LED-based, multi-wavelength NIRS oximeter for cytochrome c oxidase recovery in neonates
Biomedical Optics Express · 01.04.2026 · 17 (4) · 1649
DOI: 10.1364/boe.590418 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 04.03.2026. Verfasst von Nikola Otic und 8 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, National Institutes of Health, Advanced Research Projects Agency - Health.
Abstract (Originalsprache)
We present MW-FlexNIRS, a wearable, low-cost, LED-based, multi-wavelength near-infrared spectroscopy (NIRS) system designed for continuous monitoring of cerebral oxygenation and metabolic dynamics in neonates. The device extends the original FlexNIRS platform by integrating custom eight-wavelength LED sources, a new analog front-end, and Bluetooth low energy 5 communication onto a single flexible printed circuit board encapsulated in medical-grade silicone. To support quantitative analysis with broadband LED sources, we introduce a wavelength-weighted fitting (WWF) algorithm that explicitly accounts for LED emission spectra, photodiode responsivity, and tissue optical properties. System performance was characterized through spectral calibration, stability testing, and noise equivalent power measurements, yielding an average NEP of 123 ± 25 fW/√Hz. Validation experiments using solid silicone phantoms demonstrated accurate recovery of effective attenuation coefficients with a mean error of 2.1% using a calibrated multi-distance approach. Liquid phantom studies incorporating blood, Intralipid, and yeast were used to evaluate recovery of hemoglobin and to investigate cytochrome c oxidase (CCO) related spectral sensitivity, parameter coupling, and model limitations. Finally, a pilot measurement in a term infant with transient respiratory distress demonstrates the preliminary feasibility of stable, continuous cerebral oxygenation monitoring in the neonatal intensive care unit. Together, these results support MW-FlexNIRS as a promising platform for multi-wavelength wearable NIRS in neonates and highlight both the potential and current challenges of oxCCO quantification.
Autor:innen und Institutionen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts, USA.
- Division of Neonatology and Newborn Medicine, Department of Pediatrics, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Nikola Otic, Mitchell B Robinson, Maria Angela Franceschini, Marco Renna
Förderung
- NINDS NIH HHS
- National Institutes of Health
- Advanced Research Projects Agency - Health
Zitieren
APA
Otic, N., Robinson, M. B., Wu, K. C., Sunwoo, J., Davis, J., Kierul, O., Herzberg, E., Franceschini, M. A., & Renna, M. (2026). MW-FlexNIRS: wearable, low-cost, LED-based, multi-wavelength NIRS oximeter for cytochrome c oxidase recovery in neonates. Biomedical Optics Express, 17(4), 1649. https://doi.org/10.1364/boe.590418
Vancouver
Otic N, Robinson MB, Wu KC, Sunwoo J, Davis J, Kierul O, et al. MW-FlexNIRS: wearable, low-cost, LED-based, multi-wavelength NIRS oximeter for cytochrome c oxidase recovery in neonates. Biomedical Optics Express. 2026;17(4):1649. doi:10.1364/boe.590418
BibTeX
@article{Otic2026,
author = {Otic, Nikola and Robinson, Mitchell B and Wu, Kuan-Cheng and Sunwoo, John and Davis, Julia and Kierul, Olivia and Herzberg, Emily and Franceschini, Maria Angela and Renna, Marco},
title = {MW-FlexNIRS: wearable, low-cost, LED-based, multi-wavelength NIRS oximeter for cytochrome c oxidase recovery in neonates},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {4},
pages = {1649},
doi = {10.1364/boe.590418}
}
EUVIMED