Influence of Bone Conditions on the Accuracy of Implant Placement
Bioengineering · 18.11.2024 · 11 (11) · 1161
DOI: 10.3390/bioengineering11111161 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 18.11.2024. Verfasst von Zhicheng Gong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Technology, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai 200001, China. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Stomatological Hospital, Science and Technology Talent Project of the Shanghai Stomatological Hospital and School of Stomatology, Science and Technology Fund Project of the Shanghai Stomatological Hospital and School of Stomatology.
Abstract (Originalsprache)
This study aimed to assess the influence of cortical bone thickness, bone density, and residual ridge morphology in the posterior mandibular area on the accuracy of implant placement using tooth-supported digital guides. The research included 75 implants from 55 patients. Each patient underwent a cone-beam computed tomography (CBCT) scan for image analysis. Simplant® Pro 17 software (SIMPLANT Pro 17.01) was utilized to measure cortical bone thickness, bone density, and residual ridge morphology at the implant sites. Subsequently, 3Shape Trios software (3Shape TRIOS Design Studio 1.7.19.0) was applied to delineate optimal implant positions and design tooth-supported surgical guides. After implant treatment, the linear and angular deviations from the planned placement were quantified. Multiple linear regression, Kruskal–Wallis test, Conover–Iman test, and Bonferroni adjustment were conducted to investigate the impact of bone characteristics on implant placement precision. The tooth-supported digital guides used in this study were sufficient to fulfill the precision criteria for implant treatment. Bone density was found to significantly influence the buccal-lingual angular deviation, mesio-distal linear deviation, and mesio-distal angular deviation (p < 0.05). Additionally, significant variances were noted in the coronal deviation, apical deviation and depth deviation in buccal-lingual orientation, coronal deviation, and apical deviation in mesio-distal orientation across various residual ridge morphologies (p < 0.05). Low bone density and S-shape morphology may affect the accuracy of implant placement using tooth-supported surgical guides.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dental Technology, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai 200001, China.
- Department of Prosthodontics, Shanghai Stomatological Hospital & School of Stomatology, Shanghai Key Laboratory of Craniomaxillofacial Development and Diseases, Fudan University, Shanghai 200001, China.
- Department of Stomatology, Shanghai Seventh People's Hospital, Shanghai 200137, China.
ORCID-Profile: Shengcai Qi, Xinyi Fan
Förderung
- Shanghai Stomatological Hospital
- Science and Technology Talent Project of the Shanghai Stomatological Hospital and School of Stomatology
- Science and Technology Fund Project of the Shanghai Stomatological Hospital and School of Stomatology
Zitieren
APA
Gong, Z., Shen, Y., Qi, S., Cao, L., Fan, X., Lu, C., & Wang, J. (2024). Influence of Bone Conditions on the Accuracy of Implant Placement. Bioengineering, 11(11), 1161. https://doi.org/10.3390/bioengineering11111161
Vancouver
Gong Z, Shen Y, Qi S, Cao L, Fan X, Lu C, et al. Influence of Bone Conditions on the Accuracy of Implant Placement. Bioengineering. 2024;11(11):1161. doi:10.3390/bioengineering11111161
BibTeX
@article{Gong2024,
author = {Gong, Zhicheng and Shen, Yuyin and Qi, Shengcai and Cao, Lai and Fan, Xinyi and Lu, Chunhui and Wang, Jue},
title = {Influence of Bone Conditions on the Accuracy of Implant Placement},
journal = {Bioengineering},
year = {2024},
volume = {11},
number = {11},
pages = {1161},
doi = {10.3390/bioengineering11111161}
}