EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Effects of Exercise on the Inter-Session Accuracy of sEMG-Based Hand Gesture Recognition

Xiangyu Liu, Chenyun Dai, Jionghui Liu iD, Yangyang Yuan

Bioengineering · 2024-08-09 · 11 (8) · 811

DOI: 10.3390/bioengineering11080811 ↗

At a glance

Journal article in Bioengineering, published online on 2024-08-09. Written by Xiangyu Liu and 3 co-authors. Institution: College of Publishing, University of Shanghai for Science and Technology, Shanghai 200093, China. Cited 7 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY 4.0). Funded by: the Shanghai Sailing Program, Shanghai Sailing Program.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Surface electromyography (sEMG) is commonly used as an interface in human–machine interaction systems due to their high signal-to-noise ratio and easy acquisition. It can intuitively reflect motion intentions of users, thus is widely applied in gesture recognition systems. However, wearable sEMG-based gesture recognition systems are susceptible to changes in environmental noise, electrode placement, and physiological characteristics. This could result in significant performance degradation of the model in inter-session scenarios, bringing a poor experience to users. Currently, for noise from environmental changes and electrode shifting from wearing variety, numerous studies have proposed various data-augmentation methods and highly generalized networks to improve inter-session gesture recognition accuracy. However, few studies have considered the impact of individual physiological states. In this study, we assumed that user exercise could cause changes in muscle conditions, leading to variations in sEMG features and subsequently affecting the recognition accuracy of model. To verify our hypothesis, we collected sEMG data from 12 participants performing the same gesture tasks before and after exercise, and then used Linear Discriminant Analysis (LDA) for gesture classification. For the non-exercise group, the inter-session accuracy declined only by 2.86%, whereas that of the exercise group decreased by 13.53%. This finding proves that exercise is indeed a critical factor contributing to the decline in inter-session model performance.

Subjects

Author keywords

hand gesture recognitioninter-sessionmachine learningsurface electromyography

Authors and institutions

  • College of Publishing, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200241, China.
  • Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai 200433, China.
  • School of Information Science and Technology, Fudan University, Shanghai 200433, China.

ORCID profiles: Jionghui Liu

Funding

  • the Shanghai Sailing Program
  • Shanghai Sailing Program

Cite

APA

Liu, X., Dai, C., Liu, J., & Yuan, Y. (2024). Effects of Exercise on the Inter-Session Accuracy of sEMG-Based Hand Gesture Recognition. Bioengineering, 11(8), 811. https://doi.org/10.3390/bioengineering11080811

Vancouver

Liu X, Dai C, Liu J, Yuan Y. Effects of Exercise on the Inter-Session Accuracy of sEMG-Based Hand Gesture Recognition. Bioengineering. 2024;11(8):811. doi:10.3390/bioengineering11080811

BibTeX
@article{Liu2024,
  author = {Liu, Xiangyu and Dai, Chenyun and Liu, Jionghui and Yuan, Yangyang},
  title = {Effects of Exercise on the Inter-Session Accuracy of sEMG-Based Hand Gesture Recognition},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {8},
  pages = {811},
  doi = {10.3390/bioengineering11080811}
}
Start for free →