ACNN-BiLSTM: A Deep Learning Approach for Continuous Noninvasive Blood Pressure Measurement Using Multi-Wavelength PPG Fusion
Bioengineering · 25.03.2024 · 11 (4) · 306
DOI: 10.3390/bioengineering11040306 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 25.03.2024. Verfasst von Mou Cui und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, Natural Science Foundation of Guangxi, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments.
Abstract (Originalsprache)
As an essential physiological indicator within the human body, noninvasive continuous blood pressure (BP) measurement is critical in the prevention and treatment of cardiovascular disease. However, traditional methods of blood pressure prediction using a single-wavelength Photoplethysmographic (PPG) have bottlenecks in further improving BP prediction accuracy, which limits their development in clinical application and dissemination. To this end, this study proposed a method to fuse a four-wavelength PPG and a BP prediction model based on the attention mechanism of a convolutional neural network and bidirectional long- and short-term memory (ACNN-BiLSTM). The effectiveness of a multi-wavelength PPG fusion method for blood pressure prediction was evaluated by processing PPG signals from 162 volunteers. The study compared the performance of the PPG signals with different individual wavelengths and using a multi-wavelength PPG fusion method in blood pressure prediction, assessed using mean absolute error (MAE), root mean squared error (RMSE) and AAMI-related criteria. The experimental results showed that the ACNN-BiLSTM model achieved a better MAE ± RMSE for a systolic BP and diastolic BP of 1.67 ± 5.28 and 1.15 ± 2.53 mmHg, respectively, when using the multi-wavelength PPG fusion method. As a result, the ACNN-BiLSTM blood pressure model based on multi-wavelength PPG fusion could be considered a promising method for noninvasive continuous BP measurement.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
- National Supercomputing Center in Xi'an, Xi'an 710100, China.
- Guangxi Key Laboratory of Metabolic Reprogramming and Intelligent Medical Engineering for Chronic Diseases, Guilin 541004, China.
ORCID-Profile: Shiyong Li, Yongbo Liang
Förderung
- the National Natural Science Foundation of China
- Natural Science Foundation of Guangxi
- Guangxi Key Laboratory of Automatic Detecting Technology and Instruments
- National Natural Science Foundation of China
Zitieren
APA
Cui, M., Dong, X., Zhuang, Y., Li, S., Yin, S., Chen, Z., & Liang, Y. (2024). ACNN-BiLSTM: A Deep Learning Approach for Continuous Noninvasive Blood Pressure Measurement Using Multi-Wavelength PPG Fusion. Bioengineering, 11(4), 306. https://doi.org/10.3390/bioengineering11040306
Vancouver
Cui M, Dong X, Zhuang Y, Li S, Yin S, Chen Z, et al. ACNN-BiLSTM: A Deep Learning Approach for Continuous Noninvasive Blood Pressure Measurement Using Multi-Wavelength PPG Fusion. Bioengineering. 2024;11(4):306. doi:10.3390/bioengineering11040306
BibTeX
@article{Cui2024,
author = {Cui, Mou and Dong, Xuhao and Zhuang, Yan and Li, Shiyong and Yin, Shimin and Chen, Zhencheng and Liang, Yongbo},
title = {ACNN-BiLSTM: A Deep Learning Approach for Continuous Noninvasive Blood Pressure Measurement Using Multi-Wavelength PPG Fusion},
journal = {Bioengineering},
year = {2024},
volume = {11},
number = {4},
pages = {306},
doi = {10.3390/bioengineering11040306}
}