Multi-Wavelength PPG Amplitude Ratio Features for Cuffless Blood Pressure Estimation: An Exploratory Study
Sensors · 30.10.2026 · 26 (21) · 6897
DOI: 10.3390/s26216897 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 30.10.2026. Verfasst von Hsiao-Huang Chang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, School of Medicine, Taipei Medical University, Taipei 110301, Taiwan. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure Determination, Blood Pressure. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
Background
Cuffless blood pressure (BP) estimation from photoplethysmography (PPG) remains challenging. This exploratory study investigated whether curvature-derived waveform features from multiple PPG wavelengths, particularly amplitude ratios, are associated with cuff-based BP readings.
Methods
Red, infrared, and green PPG signals were recorded for 90 s from 48 physician-screened volunteers (23 males and 25 females; mean age, 63.41 ± 14.20 years). A single automated upper-arm cuff BP measurement was initiated approximately 2 s after each PPG recording. A curvature-based procedure identified pulse valleys, systolic peaks, dicrotic notches, and diastolic peaks, from which timing, amplitude, and amplitude ratio features were extracted. Separate linear regression models for systolic BP (SBP) and diastolic BP (DBP) were evaluated using participant-level ten-fold cross-validation. In each iteration, feature selection and model fitting were performed using only the nine training folds, and the fitted model was evaluated on the held-out fold.
Results
In the descriptive analysis across all 48 participants, amplitude ratio features involving the systolic peak and dicrotic notch showed stronger associations with cuff-based BP readings than most individual timing and amplitude features. For green-light PPG, the systolic-peak-to-dicrotic-notch amplitude ratio (RatioSN) had a correlation of approximately 0.56 with SBP and 0.48 with DBP. Based on out-of-fold predictions, the best combined-feature models achieved root mean square errors of 12.87 mmHg for SBP and 7.17 mmHg for DBP, with corresponding R2 values of 0.87 and 0.83.
Conclusions
Multi-wavelength PPG amplitude ratio features, particularly those involving the dicrotic notch, warrant further investigation for cuffless BP estimation. The substantial SBP error, small cohort, and use of a single cuff measurement obtained after each PPG recording limit interpretation. These findings do not establish clinical measurement accuracy or continuous BP tracking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, School of Medicine, Taipei Medical University, Taipei 110301, Taiwan.
- Cardiovascular Center, Taipei Veterans General Hospital, Taipei 112201, Taiwan.
- Department of Electrical Engineering, National Central University, Taoyuan 32001, Taiwan.
- School of Medicine, Fu Jen Catholic University, New Taipei City 242062, Taiwan.
- Department of Medical Research, Cathay General Hospital, Taipei 106324, Taiwan.
Förderung
- National Science and Technology Council
Zitieren
APA
Chang, H. H., Lee, T. M., Guo, S. L., & Lee, P. L. (2026). Multi-Wavelength PPG Amplitude Ratio Features for Cuffless Blood Pressure Estimation: An Exploratory Study. Sensors, 26(21), 6897. https://doi.org/10.3390/s26216897
Vancouver
Chang HH, Lee TM, Guo SL, Lee PL. Multi-Wavelength PPG Amplitude Ratio Features for Cuffless Blood Pressure Estimation: An Exploratory Study. Sensors. 2026;26(21):6897. doi:10.3390/s26216897
BibTeX
@article{Chang2026,
author = {Chang, Hsiao-Huang and Lee, Te-Min and Guo, Shu-Lin and Lee, Po-Lei},
title = {Multi-Wavelength PPG Amplitude Ratio Features for Cuffless Blood Pressure Estimation: An Exploratory Study},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6897},
doi = {10.3390/s26216897}
}
EUVIMED