EUVIMEDOpdag EUVIMED
ÜbersichtsarbeitOpen access · CC BY 4.0

Applications of Imaging Technologies in Fuchs Endothelial Corneal Dystrophy: A Narrative Literature Review

Sang Beom Han iD, Yu-Chi Liu iD, Chang Liu, Jodhbir S Mehta iD

Bioengineering · 2024-03-11 · 11 (3) · 271

DOI: 10.3390/bioengineering11030271 ↗

At a glance

Übersichtsarbeit in Bioengineering, published online on 2024-03-11. Written by Sang Beom Han and 3 co-authors. Institution: Saevit Eye Hospital, Goyang 10447, Republic of Korea. Cited 12 times so far (Crossref); 98 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Fuchs endothelial corneal dystrophy (FECD) is a complex genetic disorder characterized by the slow and progressive degeneration of corneal endothelial cells. Thus, it may result in corneal endothelial decompensation and irreversible corneal edema. Moreover, FECD is associated with alterations in all corneal layers, such as thickening of the Descemet membrane, stromal scarring, subepithelial fibrosis, and the formation of epithelial bullae. Hence, anterior segment imaging devices that enable precise measurement of functional and anatomical changes in the cornea are essential for the management of FECD. In this review, the authors will introduce studies on the application of various imaging modalities, such as anterior segment optical coherence tomography, Scheimpflug corneal tomography, specular microscopy, in vitro confocal microscopy, and retroillumination photography, in the diagnosis and monitoring of FECD and discuss the results of these studies. The application of novel technologies, including image processing technology and artificial intelligence, that are expected to further enhance the accuracy, precision, and speed of the imaging technologies will also be discussed.

Subjects

Author keywords

Fuchs endothelial corneal dystrophyanterior segment imaginganterior segment optical coherence tomographycorneal tomographyin vivo confocal microscopyspecular microscopy

Authors and institutions

  • Saevit Eye Hospital, Goyang 10447, Republic of Korea.
  • Singapore National Eye Centre, Singapore 168751, Singapore.
  • Singapore Eye Research Institute, Singapore 168751, Singapore.
  • Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore.

ORCID profiles: Sang Beom Han, Yu-Chi Liu, Jodhbir S Mehta

Cite

APA

Han, S. B., Liu, Y. C., Liu, C., & Mehta, J. S. (2024). Applications of Imaging Technologies in Fuchs Endothelial Corneal Dystrophy: A Narrative Literature Review. Bioengineering, 11(3), 271. https://doi.org/10.3390/bioengineering11030271

Vancouver

Han SB, Liu YC, Liu C, Mehta JS. Applications of Imaging Technologies in Fuchs Endothelial Corneal Dystrophy: A Narrative Literature Review. Bioengineering. 2024;11(3):271. doi:10.3390/bioengineering11030271

BibTeX
@article{Han2024,
  author = {Han, Sang Beom and Liu, Yu-Chi and Liu, Chang and Mehta, Jodhbir S},
  title = {Applications of Imaging Technologies in Fuchs Endothelial Corneal Dystrophy: A Narrative Literature Review},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {3},
  pages = {271},
  doi = {10.3390/bioengineering11030271}
}
Start for free →