Scatter Radiation Distribution to Radiographers, Nearby Patients and Caretakers during Portable and Pediatric Radiography Examinations
Bioengineering · 29.06.2023 · 10 (7) · 779
DOI: 10.3390/bioengineering10070779 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 29.06.2023. Verfasst von Shing-Yau Tam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR 999077, China. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hong Kong Polytechnic University.
Abstract (Originalsprache)
Scatter radiation from portable and pediatric X-rays could pose a risk to radiographers, nearby patients, and caretakers. We aim to evaluate the spatial scatter radiation distribution to the radiographers, nearby patients, and caretakers during common projections in portable and pediatric X-rays. We evaluated the three-dimensional scatter dose profiles of four and three commonly used portable and pediatric X-ray projections, respectively, by anthropomorphic phantoms and scatter probes. For portable X-ray, the AP abdomen had the highest scatter radiation dose recorded. Radiographer scatter radiation doses were 177 ± 8 nGy (longest cord extension) and 14 ± 0 nGy (hiding behind the portable X-ray machine). Nearby patient scatter radiation doses were 3323 ± 28 nGy (40 cm bed distance), 1785 ± 50 nGy (80 cm bed distance), and 580 ± 42 nGy (160 cm bed distance). The AP chest and abdomen had the highest scatter radiation dose in pediatric X-rays. Caretaker scatter radiation doses were 33 ± 1 nGy (50 cm height) and 659 ± 7 nGy (140 cm height). Although the estimated lens doses were all within safe levels, the use of shielding and caution on dose estimation by inverse square law is suggested to achieve the ALARA principle and dose optimization.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR 999077, China.
ORCID-Profile: Shing-Yau Tam, Edward Ting-Hei Wong
Förderung
- Hong Kong Polytechnic University
Zitieren
APA
Tam, S. Y., Fung, Y. Y., Lau, S. Y., Lam, W. N., & Wong, E. T. (2023). Scatter Radiation Distribution to Radiographers, Nearby Patients and Caretakers during Portable and Pediatric Radiography Examinations. Bioengineering, 10(7), 779. https://doi.org/10.3390/bioengineering10070779
Vancouver
Tam SY, Fung YY, Lau SY, Lam WN, Wong ET. Scatter Radiation Distribution to Radiographers, Nearby Patients and Caretakers during Portable and Pediatric Radiography Examinations. Bioengineering. 2023;10(7):779. doi:10.3390/bioengineering10070779
BibTeX
@article{Tam2023,
author = {Tam, Shing-Yau and Fung, Yuen-Ying and Lau, Sum-Yi and Lam, Wang-Ngai and Wong, Edward Ting-Hei},
title = {Scatter Radiation Distribution to Radiographers, Nearby Patients and Caretakers during Portable and Pediatric Radiography Examinations},
journal = {Bioengineering},
year = {2023},
volume = {10},
number = {7},
pages = {779},
doi = {10.3390/bioengineering10070779}
}
EUVIMED