A CFD-Integrated Parametric Framework for Evaluating Passive Carbon-Capture Enclosure Performance
Architecture · 20.04.2026 · 6 (2) · 65
DOI: 10.3390/architecture6020065 ↗Kurz gefasst
Fachartikel in der Zeitschrift Architecture, online erschienen am 20.04.2026. Verfasst von Md Shariful Alam und 1 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Washington, Mithun.
Abstract (Originalsprache)
Integrating direct air carbon capture (DAC) into buildings offers a promising pathway for reducing atmospheric CO2, yet the role of architectural design in enhancing passive carbon-capture performance remains underexplored. This study presents a computational framework developed to optimize architectural design and enclosure geometry for enhanced passive airflow, using mass-flow rate as a proxy for the comparative assessment of carbon absorption potential. Implemented within Rhino3D and Grasshopper using Ladybug and Eddy3D, the workflow integrates weather data and CFD simulation to compute segmented mass-flow rates through stacked capture trays. The framework simplifies traditionally complex CFD processes by introducing a custom segmented mass-flow calculation approach that enables comparative performance assessment during early-stage design. Results confirm the validity of the proposed workflow, revealing that façade rotation can modify total mass flow by up to 96.5%; seasonal wind variability can cause airflow to range from approximately 8.5 kg/s in January to 169.5 kg/s in May in Seattle. Spatial configuration can alter airflow by up to an order of magnitude and introduce substantial spatial heterogeneity within capture zones. This research establishes a performance-driven design framework that enables architectural geometry to actively enhance passive carbon-capture integration, positioning building design as a measurable contributor to climate mitigation strategies. Ultimately, this work bridges architectural design and carbon-capture engineering, supporting interdisciplinary approaches to scalable, climate-responsive building systems.
Förderung
- University of Washington
- Mithun
Zitieren
APA
Alam, M. S., & Abbasabadi, N. (2026). A CFD-Integrated Parametric Framework for Evaluating Passive Carbon-Capture Enclosure Performance. Architecture, 6(2), 65. https://doi.org/10.3390/architecture6020065
Vancouver
Alam MS, Abbasabadi N. A CFD-Integrated Parametric Framework for Evaluating Passive Carbon-Capture Enclosure Performance. Architecture. 2026;6(2):65. doi:10.3390/architecture6020065
BibTeX
@article{Alam2026,
author = {Alam, Md Shariful and Abbasabadi, Narjes},
title = {A CFD-Integrated Parametric Framework for Evaluating Passive Carbon-Capture Enclosure Performance},
journal = {Architecture},
year = {2026},
volume = {6},
number = {2},
pages = {65},
doi = {10.3390/architecture6020065}
}