EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Geothermal–Passive Hybrid Cooling via Courtyard-Integrated EAHE: A CFD-Based Framework for Low-Energy Residential Construction in Hot, Arid Areas

Mazin Raheem, Xiaofeng Zheng, Christopher Wood

Research and Reviews in Sustainability · 01.04.2026 · 2 · 149-161

DOI: 10.65582/rrs.2026.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research and Reviews in Sustainability, online erschienen am 01.04.2026. Verfasst von Mazin Raheem und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to severe cooling requirements and a lack of passive-geothermal system integration in residential design, achieving low-energy buildings in hot, dry climates continues to be a significant issue. Although Earth-Air Heat Exchangers (EAHEs) have shown encouraging cooling potential, there hasn't been enough research done on how to incorporate them into climate-responsive building typologies, especially courtyard housing. By incorporating an under-courtyard EAHE system into a low-energy residential building in Baghdad, Iraq, this study suggests a novel geothermal–passive hybrid cooling framework. The method improves passive cooling efficacy by combining courtyard-induced microclimatic management with subsurface thermal stability. Using ANSYS Fluent, a high-resolution Computational Fluid Dynamics (CFD) model was created to assess system performance under harsh summer circumstances (ambient temperature up to 47 °C). Important design factors were methodically optimised, such as pipe length, airflow velocity, diameter, and burial depth. The suggested system may lower the incoming air temperature to 23–28 °C, according to the results, with a maximum cooling potential that surpasses 21 °C during peak conditions. The ideal setup shows a balanced performance between thermal efficiency and pressure losses (3 m burial depth, 0.20 m pipe diameter, 60 m pipe length, and airflow velocity of 1–5 m/s). A transferable design framework for incorporating EAHE systems into courtyard-based residential architecture is presented in the study, emphasising its potential to drastically lower cooling energy use and facilitate the construction of low-energy homes in hot, dry areas. The results help close the gap between climate-responsive architecture design and geothermal technical solutions.

Zitieren

APA

Raheem, M., Zheng, X., & Wood, C. (2026). Geothermal–Passive Hybrid Cooling via Courtyard-Integrated EAHE: A CFD-Based Framework for Low-Energy Residential Construction in Hot, Arid Areas. Research and Reviews in Sustainability, 2, 149-161. https://doi.org/10.65582/rrs.2026.009

Vancouver

Raheem M, Zheng X, Wood C. Geothermal–Passive Hybrid Cooling via Courtyard-Integrated EAHE: A CFD-Based Framework for Low-Energy Residential Construction in Hot, Arid Areas. Research and Reviews in Sustainability. 2026;2:149-161. doi:10.65582/rrs.2026.009

BibTeX
@article{Raheem2026,
  author = {Raheem, Mazin and Zheng, Xiaofeng and Wood, Christopher},
  title = {Geothermal–Passive Hybrid Cooling via Courtyard-Integrated EAHE: A CFD-Based Framework for Low-Energy Residential Construction in Hot, Arid Areas},
  journal = {Research and Reviews in Sustainability},
  year = {2026},
  volume = {2},
  pages = {149--161},
  doi = {10.65582/rrs.2026.009}
}
Kostenlos starten →