Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle
AppliedPhys · 2026-06-09 · 2 (2) · 5
DOI: 10.3390/appliedphys2020005 ↗At a glance
Journal article in AppliedPhys, published online on 2026-06-09. Written by Mattia Dimitri and 2 co-authors. 18 references. The full text is freely available (open access, CC BY 4.0). Funded by: Italian Ministry of University and Research.
Abstract (original language)
Microwave (MW) ablation is a minimally invasive technique used to destroy pathological tissues through localized heating generated by a needle applicator. Internally cooled applicators using water circulation have long been the standard for high-power applications; however, water cooling introduces significant mechanical complexity. This work investigates the feasibility of a novel air-cooled coaxial thermal-ablation needle operating at 2.45 GHz up to 70 W. The system uses two concentric metal tubes—an outer 14 G stainless steel shaft (OD 2.1 mm) and an inner copper capillary (OD 1 mm, ID 0.7 mm)—serving simultaneously as the MW transmission line and cooling conduit, with dry air at room temperature (25 °C) flowing at 11 L/min under 5 bar input pressure. Experimental cooling efficiency tests demonstrated 78% efficiency for the shaft section in air and 32% for the section embedded in tissue. Electromagnetic and thermal simulations predicted ablation dimensions in a non-perfused liver of 35 mm short axis with ellipticity of 0.65 for the basic applicator, improving to 0.88 with an advanced PEEK-shaft design featuring a cancelling slot. A prototype was built and tested on exvivo bovine liver, achieving input matching better than −24 dB at 2.44 GHz and ablation dimensions (average of 5 tests) of 31 mm short axis and 45 mm long axis. Results confirm the feasibility of air cooling as a simpler, safer, and lower-cost alternative to water cooling for medium-power MW ablation.
Funding
- Italian Ministry of University and Research
Cite
APA
Dimitri, M., Ricci, M., & Gentili, G. B. (2026). Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle. AppliedPhys, 2(2), 5. https://doi.org/10.3390/appliedphys2020005
Vancouver
Dimitri M, Ricci M, Gentili GB. Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle. AppliedPhys. 2026;2(2):5. doi:10.3390/appliedphys2020005
BibTeX
@article{Dimitri2026,
author = {Dimitri, Mattia and Ricci, Martina and Gentili, Guido Biffi},
title = {Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle},
journal = {AppliedPhys},
year = {2026},
volume = {2},
number = {2},
pages = {5},
doi = {10.3390/appliedphys2020005}
}