Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle

Mattia Dimitri, Martina Ricci, Guido Biffi Gentili

AppliedPhys · 09.06.2026 · 2 (2) · 5

DOI: 10.3390/appliedphys2020005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AppliedPhys, online erschienen am 09.06.2026. Verfasst von Mattia Dimitri und 2 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of University and Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microwave (MW) ablation is a minimally invasive technique used to destroy pathological tissues through localized heating generated by a needle applicator. Internally cooled applicators using water circulation have long been the standard for high-power applications; however, water cooling introduces significant mechanical complexity. This work investigates the feasibility of a novel air-cooled coaxial thermal-ablation needle operating at 2.45 GHz up to 70 W. The system uses two concentric metal tubes—an outer 14 G stainless steel shaft (OD 2.1 mm) and an inner copper capillary (OD 1 mm, ID 0.7 mm)—serving simultaneously as the MW transmission line and cooling conduit, with dry air at room temperature (25 °C) flowing at 11 L/min under 5 bar input pressure. Experimental cooling efficiency tests demonstrated 78% efficiency for the shaft section in air and 32% for the section embedded in tissue. Electromagnetic and thermal simulations predicted ablation dimensions in a non-perfused liver of 35 mm short axis with ellipticity of 0.65 for the basic applicator, improving to 0.88 with an advanced PEEK-shaft design featuring a cancelling slot. A prototype was built and tested on exvivo bovine liver, achieving input matching better than −24 dB at 2.44 GHz and ablation dimensions (average of 5 tests) of 31 mm short axis and 45 mm long axis. Results confirm the feasibility of air cooling as a simpler, safer, and lower-cost alternative to water cooling for medium-power MW ablation.

Förderung

  • Italian Ministry of University and Research

Zitieren

APA

Dimitri, M., Ricci, M., & Gentili, G. B. (2026). Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle. AppliedPhys, 2(2), 5. https://doi.org/10.3390/appliedphys2020005

Vancouver

Dimitri M, Ricci M, Gentili GB. Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle. AppliedPhys. 2026;2(2):5. doi:10.3390/appliedphys2020005

BibTeX
@article{Dimitri2026,
  author = {Dimitri, Mattia and Ricci, Martina and Gentili, Guido Biffi},
  title = {Feasibility Study of a High-Flow Air-Cooled Metal-Tip Microwave Thermal Ablation Needle},
  journal = {AppliedPhys},
  year = {2026},
  volume = {2},
  number = {2},
  pages = {5},
  doi = {10.3390/appliedphys2020005}
}
Kostenlos starten →