EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measurement Uncertainty-Bounded Transformer Differential Protection for Islanded Converter-Dominated Power Systems

Yifan Zhao, Yu Liu, Feiyu Lin

Applied Sciences · 22.11.2026 · 16 (23) · 11570

DOI: 10.3390/app162311570 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 22.11.2026. Verfasst von Yifan Zhao und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Hubei Electric Power Co.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transformer differential protection in islanded converter-dominated systems is affected by ratio error, phase error, sampling-time mismatch, harmonic leakage, measurement noise, and current transformer (CT) abnormalities. Reliable discrimination requires the fault contribution to remain distinguishable from their combined effect. This study derives an external-state error upper bound, a fault-component lower bound, and a conditional separability margin. A trajectory-constrained observer then uses CT burden-voltage measurements to constrain shared magnetic parameters and transformer core trajectories. Fixed envelopes missed all 76 internal faults in two equivalent-source datasets, revealing the sensitivity cost of combining independent error bounds. In a separate coupled averaged converter model, the observer was evaluated using split-winding faults, uncapped hysteretic CTs, and finite-bandwidth measurements. Across 24 electromagnetic-transient records and 48 measurement replays, it detected 12/12 internal fault replays with 0/36 non-internal trips and delays of 2.8–17.2 ms. A matched two-slope comparator detected 2/12 and produced 4/36 non-internal trips. Reclosure tests detected eight repeated events; faults lasting 17 ms shortly after reclosure remained undetected and generated late actions. Within the tested model and acquisition conditions, these results indicate that shared trajectory constraints improve sensitivity while identifying the sensitivity of discrimination to post-reclosure timing.

Förderung

  • State Grid Hubei Electric Power Co

Zitieren

APA

Zhao, Y., Liu, Y., & Lin, F. (2026). Measurement Uncertainty-Bounded Transformer Differential Protection for Islanded Converter-Dominated Power Systems. Applied Sciences, 16(23), 11570. https://doi.org/10.3390/app162311570

Vancouver

Zhao Y, Liu Y, Lin F. Measurement Uncertainty-Bounded Transformer Differential Protection for Islanded Converter-Dominated Power Systems. Applied Sciences. 2026;16(23):11570. doi:10.3390/app162311570

BibTeX
@article{Zhao2026,
  author = {Zhao, Yifan and Liu, Yu and Lin, Feiyu},
  title = {Measurement Uncertainty-Bounded Transformer Differential Protection for Islanded Converter-Dominated Power Systems},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {23},
  pages = {11570},
  doi = {10.3390/app162311570}
}