Radon as an Indoor Air Quality Indicator: Ventilation-Based Mitigation, Sensing Technologies, and Data-Driven Approaches: A Review
Applied Sciences · 16.11.2026 · 16 (22) · 11331
DOI: 10.3390/app162211331 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.11.2026. Verfasst von Carlos Rizo-Maestre und 2 weiteren Autor:innen. Die Arbeit nennt 107 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Generalitat Valenciana.
Abstract (Originalsprache)
Radon, a radioactive indoor pollutant with a linear no-threshold lung-cancer link, has a building performance obligation of 100–300 Bq/m3.This systematic review, conducted in accordance with the PRISMA 2020 guidelines, screened 253 records and synthesised 103 references (94 studies plus 9 additional records). Geology establishes potential source strength; in the cases reviewed, at comparable source strength, air renewal was the dominant controllable determinant. Heat-recovery ventilation reduced radon by a median of 39%; sub-slab depressurisation exceeded 85% in a high-concentration pilot yet left 662 and 328 Bq/m3 above the 300 Bq/m3 reference level; and a barrier reduced radon by about 90%, but residuals remained above recommendations. Radon-controlled prototypes achieved 86% reductions at 34% fan runtime, from 8000 to 800 Bq/m3; infiltration-reducing retrofits were associated with 32–67% increases. Low-cost monitors showed 20–50% errors below 200 Bq/m3 (3–5% for the best field units). Within the screened literature, no peer-reviewed model-predictive or reinforcement-learning study with radon in its objective was identified; digital-twin indoor-environmental-quality frameworks omit radon. Alicante campaigns (2–22 days, passive detectors) indicate the conditions measured, not average annual exposure, without independent ≥1-season corroboration. Radon is a conditional tracer of air renewal, not a CO2, VOC or PM proxy. A decision hierarchy, a measure–model–mitigate–control framework and six gaps are proposed.
Förderung
- Generalitat Valenciana
Zitieren
APA
Rizo-Maestre, C., Echarri-Iribarren, V., & Andújar-Montoya, M. D. (2026). Radon as an Indoor Air Quality Indicator: Ventilation-Based Mitigation, Sensing Technologies, and Data-Driven Approaches: A Review. Applied Sciences, 16(22), 11331. https://doi.org/10.3390/app162211331
Vancouver
Rizo-Maestre C, Echarri-Iribarren V, Andújar-Montoya MD. Radon as an Indoor Air Quality Indicator: Ventilation-Based Mitigation, Sensing Technologies, and Data-Driven Approaches: A Review. Applied Sciences. 2026;16(22):11331. doi:10.3390/app162211331
BibTeX
@article{RizoMaestre2026,
author = {Rizo-Maestre, Carlos and Echarri-Iribarren, Victor and Andújar-Montoya, María Dolores},
title = {Radon as an Indoor Air Quality Indicator: Ventilation-Based Mitigation, Sensing Technologies, and Data-Driven Approaches: A Review},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {22},
pages = {11331},
doi = {10.3390/app162211331}
}
EUVIMED