EUVIMEDEUVIMED entdecken
Crossref

Indoor radon exposure and ventilation-driven mitigation in a high-rise residential unit using source-term-informed monitored-zone assessment

Min-Jun Kim, Chang-Hyeon Kim, Won-Jun Jang, Jae-Oh Shim

Journal of Environmental Radioactivity · 2026-11 · 300 · 108170

DOI: 10.1016/j.jenvrad.2026.108170 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Radioactivity, 2026-11. Verfasst von Min-Jun Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering/Nanoscale Environmental Sciences and Technology Institute, Wonkwang University, 460 Iksan-daero, Iksan-si, Jeonbuk…. Hauptthemen laut MEDLINE: Radon, Air Pollution, Indoor, Radiation Monitoring, Ventilation. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Wonkwang University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing airtightness in high-rise residential buildings can enhance indoor radon accumulation when persistent indoor source terms are combined with limited air exchange. This study evaluated indoor radon accumulation and ventilation-driven reduction in four monitored zones of one newly constructed high-rise residential unit using multi-point detector measurements during actual energy-recovery ventilator (ERV) operation at nominal settings of 0.3, 0.5, and 0.7 h-1, complemented by chamber-derived surface-associated radon source information and zone-specific air volumes. Paired pre-ERV concentrations ranged from 496 to 1010 Bq m-3. The combined mean detector-level reductions were 79.2%, 81.5%, and 84.0% at the three nominal settings, respectively. Relative to the 0.3 h-1 tests, the 0.5 h-1 tests had higher mean reductions and fewer residual detector locations above 148 Bq m-3, whereas the 0.7 h-1 tests had the highest combined mean reduction and shortest average response time. Multi-point measurements showed an 18.6% corner-to-center difference under closed-door conditions, indicating spatial non-uniformity within the monitored unit. The first-order mass-balance calculation was retained only as a descriptive setting-level consistency check (combined-mean RMSE 4.37 percentage points; MAE 3.11 percentage points). Effective in situ ACH was not independently verified, and each room-level condition was tested once; therefore, between-setting differences are interpreted within the tested campaign rather than as isolated causal effects of ventilation rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadonAir Pollution, IndoorRadiation MonitoringVentilationAir Pollutants, RadioactiveRadiation ExposureHousing

Stichwörter der Autor:innen

Energy recovery ventilatorIndoor radonMass-balance analysisSpatial heterogeneitySurface-associated radon source termVentilation-response assessment

Substanzen

RadonAir Pollutants, Radioactive

Autor:innen und Institutionen

  • Department of Chemical Engineering/Nanoscale Environmental Sciences and Technology Institute, Wonkwang University, 460 Iksan-daero, Iksan-si, Jeonbuk-do, 54538, Republic of Korea.
  • Department of Environmental and Safety Engineering & Energy Systems Research, Ajou University, 206 World Cup-ro, Suwon-si, Gyeonggi-do, 16499, Republic of Korea. Electronic address: wjjang@ajou.ac.kr.
  • Department of Chemical Engineering/Nanoscale Environmental Sciences and Technology Institute, Wonkwang University, 460 Iksan-daero, Iksan-si, Jeonbuk-do, 54538, Republic of Korea. Electronic address: joshim85@wku.ac.kr.

Förderung

  • Wonkwang University

Zitieren

APA

Kim, M. J., Kim, C. H., Jang, W. J., & Shim, J. O. (2026). Indoor radon exposure and ventilation-driven mitigation in a high-rise residential unit using source-term-informed monitored-zone assessment. Journal of Environmental Radioactivity, 300, 108170. https://doi.org/10.1016/j.jenvrad.2026.108170

Vancouver

Kim MJ, Kim CH, Jang WJ, Shim JO. Indoor radon exposure and ventilation-driven mitigation in a high-rise residential unit using source-term-informed monitored-zone assessment. Journal of Environmental Radioactivity. 2026;300:108170. doi:10.1016/j.jenvrad.2026.108170

BibTeX
@article{Kim2026,
  author = {Kim, Min-Jun and Kim, Chang-Hyeon and Jang, Won-Jun and Shim, Jae-Oh},
  title = {Indoor radon exposure and ventilation-driven mitigation in a high-rise residential unit using source-term-informed monitored-zone assessment},
  journal = {Journal of Environmental Radioactivity},
  year = {2026},
  volume = {300},
  pages = {108170},
  doi = {10.1016/j.jenvrad.2026.108170}
}
Kostenlos starten →