EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermal and Operational Performance of Gravity Loop Heat Pipes with Flat and Finned-Tube Evaporators in a Gas Fireplace Insert

Ľudmila Nová, Patrik Nemec, Jozef Jandačka, Milan Malcho, Andrej Kordoš, Ivan Martinček

Applied Sciences · 06.11.2026 · 16 (21) · 10995

DOI: 10.3390/app162110995 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 06.11.2026. Verfasst von Ľudmila Nová und 5 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: VEGA agency, KEGA agency, University of Žilina.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Evaporator designs of passive heat pipes for combustion air preheating in local space heaters have not been compared directly. This study compares two complete evaporator designs of a gravity loop heat pipe in a gas fireplace insert: a flat evaporator with a glass-fibre wick and a copper finned-tube evaporator. Two test series at four settings (4.5–9.6 kW) were compared with a reference without the heat pipe. The heat pipe transferred 953–2040 W to the combustion air (point velocity upper estimate; 523–1202 W from the excess air ratio), preheating it to 50–85 °C. The EN 613 efficiency rose by 1.5–5.7 percentage points at the combustion chamber boundary but changed by only −1.1 to +1.2 for the whole insert, as the evaporator also absorbs firebox radiation and preheating heat largely circulates internally. The finned-tube evaporator started up faster (10–29 vs. 33–42 min), but its series differed by up to 25%. At the highest settings, the flat evaporator lowered the flue gas temperature by 14–15 K but raised the glass temperature by 46–59 K. Loop pressures up to 6.6 bar limited operation. The evaporator design thus mainly affected start-up and firebox and flue gas temperatures; whole-appliance efficiency gains require lower flue gas temperatures.

Förderung

  • VEGA agency
  • KEGA agency
  • University of Žilina

Zitieren

APA

Nová, Ľ., Nemec, P., Jandačka, J., Malcho, M., Kordoš, A., & Martinček, I. (2026). Thermal and Operational Performance of Gravity Loop Heat Pipes with Flat and Finned-Tube Evaporators in a Gas Fireplace Insert. Applied Sciences, 16(21), 10995. https://doi.org/10.3390/app162110995

Vancouver

Nová Ľ, Nemec P, Jandačka J, Malcho M, Kordoš A, Martinček I. Thermal and Operational Performance of Gravity Loop Heat Pipes with Flat and Finned-Tube Evaporators in a Gas Fireplace Insert. Applied Sciences. 2026;16(21):10995. doi:10.3390/app162110995

BibTeX
@article{Nov2026,
  author = {Nová, Ľudmila and Nemec, Patrik and Jandačka, Jozef and Malcho, Milan and Kordoš, Andrej and Martinček, Ivan},
  title = {Thermal and Operational Performance of Gravity Loop Heat Pipes with Flat and Finned-Tube Evaporators in a Gas Fireplace Insert},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {10995},
  doi = {10.3390/app162110995}
}
Kostenlos starten →