The Influence of Finned Tube Parameters on Heat Transfer in Shell and Tube Heat Exchangers
Applied Sciences · 11.05.2026 · 16 (10) · 4782
DOI: 10.3390/app16104782 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 11.05.2026. Verfasst von Yamei Lan und 2 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program, Shanghai Natural Science Foundation.
Abstract (Originalsprache)
Nine sets of fin parameter combinations, including a plain tube control group, were modeled. Simulations were performed under steady-state conditions using the EWT Realizable k-ε turbulence model, with benzene and water as working fluids, while accounting for temperature-dependent thermophysical properties. Flow field distribution, temperature profile, Nusselt number, and pressure drop in the shell side of the heat exchanger were analyzed. Response surface methodology was employed to systematically evaluate the coupled effects of fin height and fin spacing on thermal performance. The results indicate that annular fins significantly enhance heat transfer by inducing secondary flow and disrupting the thermal boundary layer. Compared to the smooth tube, the finned tubes increased the Nusselt number (Nu) by up to 28.6% and the total heat transfer rate by 13.55%, while the pressure drop (ΔP) increased by approximately 9.81% to 16.5%. The analysis revealed that fin height is the dominant factor affecting performance, whereas fin spacing plays a regulatory role. As the fins became taller or denser, the temperature field evolved from stable stratification to intense mixing and eventually to local disorder. The study identified an optimal parameter range for engineering applications. A fin height of 2–3 mm combined with a spacing of 10–15 mm achieves the best balance between heat transfer enhancement and flow resistance. Specifically, the combination of h = 3 mm and s = 10 mm yielded the highest Energy Efficiency Coefficient (EEC) of 1.567. This configuration is recommended for large-flow, pressure-drop-sensitive systems, such as those found in petrochemical plants or long-distance heat transmission applications.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program
- Shanghai Natural Science Foundation
Zitieren
APA
Lan, Y., Li, H., & Yi, W. (2026). The Influence of Finned Tube Parameters on Heat Transfer in Shell and Tube Heat Exchangers. Applied Sciences, 16(10), 4782. https://doi.org/10.3390/app16104782
Vancouver
Lan Y, Li H, Yi W. The Influence of Finned Tube Parameters on Heat Transfer in Shell and Tube Heat Exchangers. Applied Sciences. 2026;16(10):4782. doi:10.3390/app16104782
BibTeX
@article{Lan2026,
author = {Lan, Yamei and Li, Haoran and Yi, Wulang},
title = {The Influence of Finned Tube Parameters on Heat Transfer in Shell and Tube Heat Exchangers},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {10},
pages = {4782},
doi = {10.3390/app16104782}
}
EUVIMED