Comparative Analysis Between the Classical Least Squares (CLS) Algorithm and Partial Least Squares Analysis for the Study of CBD and THC Content in Cannabis Oil Samples Analyzed Using FT-IR ATR
Applied Sciences · 01.10.2026 · 16 (19) · 9748
DOI: 10.3390/app16199748 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 01.10.2026. Verfasst von Deymis Albor-Patiño und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: General Royalties System of the Department of Atlántico-Colombia.
Abstract (Originalsprache)
Reliable analytical methods for quantifying the major phytocannabinoids cannabidiol (CBD) and Δ9-tetrahydrocannabinol (Δ9-THC) are essential to ensure quality control and regulatory compliance of cannabis-derived products. This study evaluated attenuated total reflectance Fourier-transform infrared spectroscopy (FTIR-ATR), combined with Partial Least Squares (PLS) and Classical Least Squares (CLS) chemometric models, to quantify cannabinoids in cannabis extract oils. FTIR-ATR spectra were collected over 4000–400 cm−1 and processed using principal component analysis (PCA), Multiplicative Scatter Correction (MSC), and multivariate calibration. The PLS model, built on the optimal spectral regions of 1000–1800 cm−1 and 3500 cm−1 and validated by leave-one-out cross-validation, achieved strong predictive performance (RMSEC = 0.559%, RMSECV = 0.675%; R2cal = 0.910, R2cv = 0.869), indicating good predictive ability with no evidence of overfitting. Notably, the variables with the highest VIP scores were mainly associated with the extract-to-diluent ratio rather than CBD-specific absorbance bands. The CLS model, in turn, showed excellent agreement for pure cannabinoid standards (MSE on the order of 10−6; β coefficients between 0.98 and 0.99) but performed poorly in complex matrices, yielding negative coefficients for several samples. This limitation stems from unmodeled matrix components and the near-collinearity of the THC and CBD infrared spectra, which renders the CLS system ill-conditioned and causes noise to redistribute between the two basis vectors. Taken together, these findings indicate that the FTIR-ATR/PLS approach offers a robust, rapid, and cost-effective alternative for routine cannabinoid analysis. In contrast, the CLS model remains valuable for residual-based detection of unmodeled spectral contributions that may signal sample anomalies or contamination.
Förderung
- General Royalties System of the Department of Atlántico-Colombia
Zitieren
APA
Albor-Patiño, D., Romero, M., Ramos-Hernández, A., Arana, V., Gómez, C. M., Álzate, J. V., Londoño, L. P., & Ospina-Castro, M. (2026). Comparative Analysis Between the Classical Least Squares (CLS) Algorithm and Partial Least Squares Analysis for the Study of CBD and THC Content in Cannabis Oil Samples Analyzed Using FT-IR ATR. Applied Sciences, 16(19), 9748. https://doi.org/10.3390/app16199748
Vancouver
Albor-Patiño D, Romero M, Ramos-Hernández A, Arana V, Gómez CM, Álzate JV, et al. Comparative Analysis Between the Classical Least Squares (CLS) Algorithm and Partial Least Squares Analysis for the Study of CBD and THC Content in Cannabis Oil Samples Analyzed Using FT-IR ATR. Applied Sciences. 2026;16(19):9748. doi:10.3390/app16199748
BibTeX
@article{AlborPatio2026,
author = {Albor-Patiño, Deymis and Romero, Mario and Ramos-Hernández, Andrea and Arana, Victoria and Gómez, Carlos Meléndez and Álzate, Jolián Vargas and Londoño, Leonardo Pacheco and Ospina-Castro, María},
title = {Comparative Analysis Between the Classical Least Squares (CLS) Algorithm and Partial Least Squares Analysis for the Study of CBD and THC Content in Cannabis Oil Samples Analyzed Using FT-IR ATR},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {19},
pages = {9748},
doi = {10.3390/app16199748}
}
EUVIMED