Mass-Balance Validation in Bench-Scale Gravimetric Sorption Testing: A Case Study on Zeolite and Clay for Used Motor Oil and Diesel Fuel
Applied Sciences · 07.08.2026 · 16 (16) · 7865
DOI: 10.3390/app16167865 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 07.08.2026. Verfasst von Irina Maria Chidean und 2 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Gravimetric sorption testing is widely used to screen candidate sorbents for petroleum hydrocarbon remediation. Using a five-material Romanian sorbent screening as a case study, this study demonstrates why explicit mass-balance validation should be mandatory in such protocols. Natural zeolite, clay, peat, wood sawdust, and hops were tested against used motor oil and diesel fuel under a standardized protocol. A mass-balance check showed that results for peat, wood sawdust, and hops implied hydrocarbon uptakes exceeding the physically available mass; because the underlying raw records could not be located, these three datasets were excluded, illustrating the kind of error such validation is designed to catch. The validated result is a two-material comparison: for used motor oil and diesel fuel, respectively, clay and zeolite showed the higher sorption capacity (1.210 ± 0.016 g/g vs. 1.170 ± 0.010 g/g, Welch’s t-test, t(6.7) = −4.78, p = 0.0022; and 1.444 ± 0.005 g/g vs. 1.352 ± 0.031 g/g, t(4.2) = 6.51, p = 0.0023), a reversal consistent with, but not confirmed by, a pore-size- and viscosity-selective sorption hypothesis. Both materials showed low inter-replicate variability (CV < 2.3%), confirmed by Mann–Whitney U tests (p = 0.0079 for both hydrocarbons). Because measured capacities are three- to thirteen-fold higher than literature values for raw clinoptilolite and bentonite, these results are presented as protocol-specific bench-scale rankings rather than generalizable material properties. This study is offered as a worked example of validation-first data screening in gravimetric sorption testing; deeper characterization and re-measurement of the excluded materials are identified as next steps.
Zitieren
APA
Chidean, I. M., Rusu, T. A., & Rusu, T. (2026). Mass-Balance Validation in Bench-Scale Gravimetric Sorption Testing: A Case Study on Zeolite and Clay for Used Motor Oil and Diesel Fuel. Applied Sciences, 16(16), 7865. https://doi.org/10.3390/app16167865
Vancouver
Chidean IM, Rusu TA, Rusu T. Mass-Balance Validation in Bench-Scale Gravimetric Sorption Testing: A Case Study on Zeolite and Clay for Used Motor Oil and Diesel Fuel. Applied Sciences. 2026;16(16):7865. doi:10.3390/app16167865
BibTeX
@article{Chidean2026,
author = {Chidean, Irina Maria and Rusu, Tudor Andrei and Rusu, Tiberiu},
title = {Mass-Balance Validation in Bench-Scale Gravimetric Sorption Testing: A Case Study on Zeolite and Clay for Used Motor Oil and Diesel Fuel},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {16},
pages = {7865},
doi = {10.3390/app16167865}
}
EUVIMED