EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of AI-Measured Overjet and Overbite of Cephalometry Compared to Manual Measurement

Bijan Ganjali, Mohamad Talal Radwan, Zahir Altuğ

Applied Sciences · 24.07.2026 · 16 (15) · 7404

DOI: 10.3390/app16157404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 24.07.2026. Verfasst von Bijan Ganjali und 2 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the reliability of artificial intelligence (AI)-based cephalometric measurements of overjet (OJ) and overbite (OB) and their agreement with manual assessment and investigated factors that may influence measurement outcomes. This retrospective cross-sectional study included 200 orthodontic patients (125 females, 75 males; mean age 20.12 years) selected from 440 records. Manual OJ and OB measurements were obtained twice from dental models using digital calipers and served as the reference standard. AI-based measurements were generated from lateral cephalometric radiographs using WebCeph™. Reliability was assessed using intraclass correlation coefficients (ICCs), while agreement between methods was evaluated using paired t-tests and Bland–Altman analysis. AI-based measurements showed significantly higher OJ and slightly lower OB values than manual measurements, with mean differences of 0.89 mm for OJ and −0.44 mm for OB (p < 0.05). Intra- and inter-examiner reliability were excellent (ICCs > 0.90). Bland–Altman analysis demonstrated that most measurement differences were within the 95% limits of agreement despite a small systematic bias. These findings suggest that AI-assisted cephalometric analysis provides a rapid and reliable approach for routine orthodontic assessment; however, individual discrepancies may be clinically relevant when high measurement precision is required. Therefore, AI should be considered a useful adjunct to conventional assessment, whereas manual measurements remain the reference standard when maximum measurement accuracy is essential.

Zitieren

APA

Ganjali, B., Radwan, M. T., & Altuğ, Z. (2026). Accuracy of AI-Measured Overjet and Overbite of Cephalometry Compared to Manual Measurement. Applied Sciences, 16(15), 7404. https://doi.org/10.3390/app16157404

Vancouver

Ganjali B, Radwan MT, Altuğ Z. Accuracy of AI-Measured Overjet and Overbite of Cephalometry Compared to Manual Measurement. Applied Sciences. 2026;16(15):7404. doi:10.3390/app16157404

BibTeX
@article{Ganjali2026,
  author = {Ganjali, Bijan and Radwan, Mohamad Talal and Altuğ, Zahir},
  title = {Accuracy of AI-Measured Overjet and Overbite of Cephalometry Compared to Manual Measurement},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {7404},
  doi = {10.3390/app16157404}
}
Kostenlos starten →