EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of automated analysis in cephalometry

Réka Bagdy-Bálint, Gergely Szabó, Örkény H Zováthi, Bendegúz H Zováthi, Ábris Somorjai, Csenge Köpenczei, Noémi Katinka Rózsa

Journal of Dental Sciences · 2025-04 · 20 (2) · 830-843

DOI: 10.1016/j.jds.2024.09.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dental Sciences, 2025-04. Verfasst von Réka Bagdy-Bálint und 6 weiteren Autor:innen. Beteiligte Einrichtung: Semmelweis University, Department of Paediatric Dentistry and Orthodontics, Budapest, Hungary. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Semmelweis Egyetem.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/purpose: Artificial intelligence (AI) has been widely used in medicine, including orthodontics. The aim of this study was to investigate the training process of a cascaded Convolutional Neural Network (CNN), built for landmark detection on various qualities of lateral cephalograms and to determine the speed, reliability and clinical accuracy of an algorithm for orthodontic diagnosis. Materials and methods: The CNN model was trained on a total of 1600 lateral cephalograms. After each training datasets (input of 400, 800, 1200, 1600 images) were added, the model was evaluated on a test set containing 78 images of varying quality. We measured the accuracy of AI-based landmark detection by statistical analysis of intra- and interexaminer distance errors, as well as examiner versus model predictions, furthermore by prognosis of consecutive diagnostic failures.

Results

There was a clear improvement in time efficiency (5.25 min), and substantial improvements were observed during the training process. In terms of accuracy, based on Euclidean distance error measurements, the best model provided more consistent dot tracing than two different examiners or the same examiner on two different occasions. Angular (0.05°-1.86°) and proportional (3.14%) errors, measured by the best model, were considered clinically acceptable.

Conclusion

The application of a proper AI-algorithm for orthodontic cephalometric analysis results in lower variability between models than the variability observed among experts. AI predictions supported the examiners in finding the correct location of the specific landmarks more accurately and in less time as the training of the automatic prediction model improved. Further research could investigate the therapeutic consequences.

Schlagwörter

Stichwörter der Autor:innen

Artificial intelligenceAutomationCephalometryClinical decision-makingComputer-assistedDiagnosis

Autor:innen und Institutionen

  • Semmelweis University, Department of Paediatric Dentistry and Orthodontics, Budapest, Hungary.
  • Pázmány Péter Catholic University, Budapest, Hungary.
  • Ceph Assistant Ltd., Budapest, Hungary.

Förderung

  • Semmelweis Egyetem

Zitieren

APA

Bagdy-Bálint, R., Szabó, G., Zováthi, Ö. H., Zováthi, B. H., Somorjai, Á., Köpenczei, C., & Rózsa, N. K. (2025). Accuracy of automated analysis in cephalometry. Journal of Dental Sciences, 20(2), 830-843. https://doi.org/10.1016/j.jds.2024.09.012

Vancouver

Bagdy-Bálint R, Szabó G, Zováthi ÖH, Zováthi BH, Somorjai Á, Köpenczei C, et al. Accuracy of automated analysis in cephalometry. Journal of Dental Sciences. 2025;20(2):830-843. doi:10.1016/j.jds.2024.09.012

BibTeX
@article{BagdyBlint2025,
  author = {Bagdy-Bálint, Réka and Szabó, Gergely and Zováthi, Örkény H and Zováthi, Bendegúz H and Somorjai, Ábris and Köpenczei, Csenge and Rózsa, Noémi Katinka},
  title = {Accuracy of automated analysis in cephalometry},
  journal = {Journal of Dental Sciences},
  year = {2025},
  volume = {20},
  number = {2},
  pages = {830--843},
  doi = {10.1016/j.jds.2024.09.012}
}
Kostenlos starten →