Energy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study
Applied Sciences · 05.04.2026 · 16 (7) · 3550
DOI: 10.3390/app16073550 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 05.04.2026. Verfasst von Gerardo Roque und 8 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BMBF, MINCIENCIAS, Universidad de los Andes, Faculty of Science.
Abstract (Originalsprache)
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility because strong attenuation lowers contrast, while conventional rhodium (Rh) K-edge filtering suppresses part of the high-energy spectral tail. This study presents a Monte Carlo framework for spectroscopic mammography using a voxelated 1 mm thick cadmium telluride (CdTe) sensor and a first-order detector interaction model to evaluate energy-dependent image quality. The model reproduces fluorescence and inter-voxel energy redistribution in CdTe, but not the full detector chain, and remains idealized with respect to charge transport, carrier collection, threshold dispersion, and pile-up. Energy-resolved simulations in the 10–50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and to form integrated-spectrum (IS) images for four tested spectra. For the dense-breast calcium hydroxyapatite (HA) speck detection task considered here, and under the present simulation assumptions, replacing the standard 28 kVp + 50 μm Rh spectrum with 28 kVp + 1 mm Al increased the simulated IS image CNR by 23.11%, with an approximately 5% increase in estimated primary-incident air kerma at the phantom entrance plane. Preliminary experimental implant-phantom images were included as a qualitative feasibility check, showing a trend consistent with simulations. Within the limits of this task-specific simulation, the results suggest that preserving the transmitted high-energy tail can improve HA speck visibility for the present 1 mm CdTe photon-counting detector, with the 28 kVp + 1 mm Al spectrum outperforming the other tested cases.
Förderung
- BMBF
- MINCIENCIAS
- Universidad de los Andes, Faculty of Science
Zitieren
APA
Roque, G., Pérez-Lara, M. L., Cely, S., Parra, J. S. U., Bermúdez, J. D., Schütz, M. K., Fiederle, M., Ávila, C., & Procz, S. (2026). Energy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study. Applied Sciences, 16(7), 3550. https://doi.org/10.3390/app16073550
Vancouver
Roque G, Pérez-Lara ML, Cely S, Parra JSU, Bermúdez JD, Schütz MK, et al. Energy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study. Applied Sciences. 2026;16(7):3550. doi:10.3390/app16073550
BibTeX
@article{Roque2026,
author = {Roque, Gerardo and Pérez-Lara, Maria Laura and Cely, Steven and Parra, Juan Sebastián Useche and Bermúdez, Jesús David and Schütz, Michael K. and Fiederle, Michael and Ávila, Carlos and Procz, Simon},
title = {Energy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study},