EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electroluminescent Sensing Coating for On-Line Detection of Zero-Value Insulators in High-Voltage Systems

Yongjie Nie, Yihang Jiang, Pengju Wang, Daoyuan Chen, Yongsen Han, Jialiang Song, Yuanwei Zhu, Shengtao Li

Applied Sciences · 17.07.2025 · 15 (14) · 7965

DOI: 10.3390/app15147965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.07.2025. Verfasst von Yongjie Nie und 7 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Southern Power Grid, National Natural Science Foundation of China, Key R&D Projects in Shaanxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In high-voltage transmission lines, insulators subjected to prolonged electromechanical stress are prone to zero-value defects, leading to insulation failure and posing significant risks to power grid reliability. The conventional detection method of spark gap is vulnerable to environmental interference, while the emerging electric field distribution-based techniques require complex instrumentation, limiting its applications in scenes of complex structures and atop tower climbing. To address these challenges, this study proposes an electroluminescent sensing strategy for zero-value insulator identification based on the electroluminescence of ZnS:Cu. Based on the stimulation of electrical stress, real-time monitoring of the health status of insulators was achieved by applying the composite of epoxy and ZnS:Cu onto the connection area between the insulator steel cap and the shed. Experimental results demonstrate that healthy insulators exhibit characteristic luminescence, whereas zero-value insulators show no luminescence due to a reduced drop in electrical potential. Compared with conventional detection methods requiring access of electric signals, such non-contact optical detection method offers high fault-recognition accuracy and real-time response capability within milliseconds. This work establishes a novel intelligent sensing paradigm for visualized condition monitoring of electrical equipment, demonstrating significant potential for fault diagnosis in advanced power systems.

Förderung

  • China Southern Power Grid
  • National Natural Science Foundation of China
  • Key R&D Projects in Shaanxi Province
  • Youth Fund of State Key Laboratory of Electrical Insulation and Power Equipment
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Nie, Y., Jiang, Y., Wang, P., Chen, D., Han, Y., Song, J., Zhu, Y., & Li, S. (2025). Electroluminescent Sensing Coating for On-Line Detection of Zero-Value Insulators in High-Voltage Systems. Applied Sciences, 15(14), 7965. https://doi.org/10.3390/app15147965

Vancouver

Nie Y, Jiang Y, Wang P, Chen D, Han Y, Song J, et al. Electroluminescent Sensing Coating for On-Line Detection of Zero-Value Insulators in High-Voltage Systems. Applied Sciences. 2025;15(14):7965. doi:10.3390/app15147965

BibTeX
@article{Nie2025,
  author = {Nie, Yongjie and Jiang, Yihang and Wang, Pengju and Chen, Daoyuan and Han, Yongsen and Song, Jialiang and Zhu, Yuanwei and Li, Shengtao},
  title = {Electroluminescent Sensing Coating for On-Line Detection of Zero-Value Insulators in High-Voltage Systems},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {14},
  pages = {7965},
  doi = {10.3390/app15147965}
}
Kostenlos starten →