An Evaluation of the ASTar Automated Antimicrobial Testing System for Gram-Negative Bacteria in Positive Blood Cultures
Antibiotics · 01.03.2025 · 14 (3) · 249
DOI: 10.3390/antibiotics14030249 ↗Kurz gefasst
Fachartikel in der Zeitschrift Antibiotics, online erschienen am 01.03.2025. Verfasst von Hannah Coulson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Microbiology Department, Freeman Hospital, Newcastle upon Tyne NE7 7DN, UK. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Prompt administration of optimal antibiotic therapy is essential in the management of bacteraemia to reduce morbidity and mortality and to facilitate antibiotic stewardship. To identify the most effective therapy, rapid and accurate antimicrobial susceptibility testing (AST) is essential. ASTar is an automated AST system that delivers minimum inhibitory concentrations (MICs) for 23 antimicrobials and is designed for testing Gram-negative bacteria directly from positive blood cultures, with results available after 6 h.
Methods
The ASTar system was evaluated with 64 positive blood cultures from patients with bacteraemia and 56 simulated blood cultures inoculated with a range of antibiotic-resistant isolates. The ASTar results for 12 antibiotics commonly used in our hospitals were compared with the results derived from three different methods of disc susceptibility testing and MICs determined by broth microdilution (BMD).
Results
For 121 isolates of Gram-negative bacteria, ASTar showed an average essential agreement of 87.2% and an average categorical agreement of 94%, when compared with BMD. Very major errors (false susceptibility) and major errors (false resistance) were associated with 0.9% and 3.4% of results, respectively. The results were at least as accurate as those obtained from EUCAST disc susceptibility methods (both rapid and overnight methods).
Conclusions
The ASTar system is an effective method for delivering accurate and rapid (6 h) AST results for Gram-negative bacteria by the direct testing of positive blood cultures.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Microbiology Department, Freeman Hospital, Newcastle upon Tyne NE7 7DN, UK.
ORCID-Profile: Kathryn M Day, Danielle J C Fenwick, Emma C L Marrs, John D Perry
Zitieren
APA
Coulson, H., Ivin, A., Day, K. M., Fenwick, D. J. C., Marrs, E. C. L., Mpwilu, P., & Perry, J. D. (2025). An Evaluation of the ASTar Automated Antimicrobial Testing System for Gram-Negative Bacteria in Positive Blood Cultures. Antibiotics, 14(3), 249. https://doi.org/10.3390/antibiotics14030249
Vancouver
Coulson H, Ivin A, Day KM, Fenwick DJC, Marrs ECL, Mpwilu P, et al. An Evaluation of the ASTar Automated Antimicrobial Testing System for Gram-Negative Bacteria in Positive Blood Cultures. Antibiotics. 2025;14(3):249. doi:10.3390/antibiotics14030249
BibTeX
@article{Coulson2025,
author = {Coulson, Hannah and Ivin, Angelo and Day, Kathryn M and Fenwick, Danielle J C and Marrs, Emma C L and Mpwilu, Patrick and Perry, John D},
title = {An Evaluation of the ASTar Automated Antimicrobial Testing System for Gram-Negative Bacteria in Positive Blood Cultures},
journal = {Antibiotics},
year = {2025},
volume = {14},
number = {3},
pages = {249},
doi = {10.3390/antibiotics14030249}
}
EUVIMED