EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access

Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures

James W Snyder iD, Nadia Chaudhry, Wesley Hoffmann iD

Journal of Clinical Microbiology · 11.12.2024 · 62 (12)

DOI: 10.1128/jcm.00922-24 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Clinical Microbiology, erschienen am 11.12.2024. Verfasst von James W Snyder und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Section of Clinical Microbiology and Infectious Diseases Molecular Diagnostics, University of Louisv…. Hauptthemen laut MEDLINE: Microbial Sensitivity Tests, Blood Culture, Anti-Bacterial Agents, Gram-Negative Bacteria. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid antimicrobial susceptibility testing (rAST) performed directly from blood cultures is essential to influencing the selection of appropriate antibiotics, preferably targeted therapy, for the treatment of bloodstream infections. Affinity Biosensors has developed the LifeScale, a phenotypic rAST system based on microfluidic sensors with a mechanical resonator that measures the mass of individual microbes. The combination of replication, biomass, and population profiling of individual microbes is analyzed to produce rAST results. The performance of the LifeScale was evaluated and compared to our current standard of care (SOC) antimicrobial susceptibility testing (AST) system under clinical conditions. The results indicated that the LifeScale is easy to use and provides rapid, reliable, and accurate AST results in less than 5 h directly from from positive blood cultures containing Gram-negative organisms listed in the current database. For all organism–antibiotic combinations involving polymicrobial cultures, LifeScale showed a resistant result when either mixed isolate was resistant. If these results prove to be robust on further testing, this may justify the reporting of rapid LifeScale results without the need for additional confirmatory testing. IMPORTANCE This is the first clinical-based study of a unique technology using microfluidic sensors to generate rapid antimicrobial susceptibility test results directly from blood cultures containing Gram-negative rods. The issue of polymicrobial cultures was also addressed in this study, which, to our knowledge, has not been addressed in publications of other rapid phenotypic AST systems. Overall, LifeScale results compared favorably with the SOC in terms of overall agreement, especially categorical agreement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microbial Sensitivity TestsBlood CultureAnti-Bacterial AgentsGram-Negative BacteriaHumansGram-Negative Bacterial InfectionsBacteremiaAutomation, LaboratoryTime FactorsBiosensing Techniques

Stichwörter der Autor:innen

Gram stainGram-negative bacteriaMALDI-TOFMicroScanVerigeneantimicrobial stewarshipantimicrobial susceptibility testingblood culutresmicrofluidicspolymicrobial

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Pathology and Laboratory Medicine, Section of Clinical Microbiology and Infectious Diseases Molecular Diagnostics, University of Louisville, Louisville, Kentucky, USA.
  • UofL Healthcare System, Louisville, Kentucky, USA.

ORCID-Profile: James W Snyder, Wesley Hoffmann

Zitieren

APA

Snyder, J. W., Chaudhry, N., & Hoffmann, W. (2024). Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures. Journal of Clinical Microbiology, 62(12). https://doi.org/10.1128/jcm.00922-24

Vancouver

Snyder JW, Chaudhry N, Hoffmann W. Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures. Journal of Clinical Microbiology. 2024;62(12). doi:10.1128/jcm.00922-24

BibTeX
@article{Snyder2024,
  author = {Snyder, James W and Chaudhry, Nadia and Hoffmann, Wesley},
  title = {Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures},
  journal = {Journal of Clinical Microbiology},
  year = {2024},
  volume = {62},
  number = {12},
  doi = {10.1128/jcm.00922-24}
}
Kostenlos starten →