EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep Learning-Based Automated Anatomical Landmark Detection and Saw Blade Size Prediction for Canine Tibial Plateau Leveling Osteotomy

Tea Hyung Kim iD, Ji Yun Lee, Hwi Yool Kim iD

Animals · 24.05.2026 · 16 (11) · 1599

DOI: 10.3390/ani16111599 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Animals, online erschienen am 24.05.2026. Verfasst von Tea Hyung Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine, Konkuk University, Seoul 05029, Republic of Korea. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To develop and validate a fully automated deep learning workflow that localizes key anatomical landmarks on standard canine hindlimb lateral radiographs, derives the tibial plateau angle (TPA), and recommends a saw blade size for tibial plateau leveling osteotomy (TPLO) preoperative planning. Study Design: Retrospective validation study. Animals: Two hundred annotated lateral radiographs obtained from 130 dogs representing 14 breeds, with body weights ranging from 2.4 to 38.0 kg.

Methods

A customized four-stage U-Net was trained using three complementary grayscale representations (normalized, contrast-enhanced, and gamma-adjusted images) to detect five TPLO-related landmarks. A deterministic geometric module then calculated TPA and mapped the derived osteotomy geometry to the nearest clinically available saw blade class.

Results

The mean absolute error for TPA prediction was 1.34 ± 1.73°, and the median absolute error was 0.75°. Overall, 164/200 cases (82.0%) were within 2° and 188/200 cases (94.0%) were within 4.8° of the surgeon reference. Mean bias was −0.39°, the 95% limits of agreement ranged from −4.62° to 3.85°, and Pearson’s correlation coefficient was 0.87. For saw blade size prediction, mean absolute error was 0.32 ± 0.85 mm, exact agreement was achieved in 175/200 cases (87.5%), and all predictions remained within one adjacent class.

Conclusions

The proposed pipeline provided clinically useful automated estimates of TPA and saw blade size from routine lateral radiographs. However, occasional high-impact landmark failures remained, indicating that the system should be positioned as an interpretable decision-support tool that requires surgeon verification rather than as an unsupervised autonomous planning system.

Schlagwörter

Stichwörter der Autor:innen

TPLOdeep learningdoglandmark detectionpreoperative planningradiographytibial plateau angleveterinary orthopedics

Autor:innen und Institutionen

  • Department of Veterinary Medicine, Konkuk University, Seoul 05029, Republic of Korea.
  • Digital Strategy Team, Chung-Ang University Healthcare System, Seoul 06973, Republic of Korea.

ORCID-Profile: Tea Hyung Kim, Hwi Yool Kim

Zitieren

APA

Kim, T. H., Lee, J. Y., & Kim, H. Y. (2026). Deep Learning-Based Automated Anatomical Landmark Detection and Saw Blade Size Prediction for Canine Tibial Plateau Leveling Osteotomy. Animals, 16(11), 1599. https://doi.org/10.3390/ani16111599

Vancouver

Kim TH, Lee JY, Kim HY. Deep Learning-Based Automated Anatomical Landmark Detection and Saw Blade Size Prediction for Canine Tibial Plateau Leveling Osteotomy. Animals. 2026;16(11):1599. doi:10.3390/ani16111599

BibTeX
@article{Kim2026,
  author = {Kim, Tea Hyung and Lee, Ji Yun and Kim, Hwi Yool},
  title = {Deep Learning-Based Automated Anatomical Landmark Detection and Saw Blade Size Prediction for Canine Tibial Plateau Leveling Osteotomy},
  journal = {Animals},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {1599},
  doi = {10.3390/ani16111599}
}
Kostenlos starten →