EUVIMEDEUVIMED entdecken
Crossref

Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study

Diogo Miraldo iD, Rodrigo Alvarez iD, Maria Zurita iD

Veterinary and Comparative Orthopaedics and Traumatology · 01.01.2026 · 39 (01) · 047-053

DOI: 10.1055/a-2649-9074 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.01.2026. Verfasst von Diogo Miraldo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Southern Counties Veterinary Specialists, Hampshire, United Kingdom. Hauptthemen laut MEDLINE: Osteotomy, Bone Plates, Tibia. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To compare immediate, static interfragmentary compression patterns of three tibial plateau leveling osteotomy (TPLO) plate designs. TPLO was performed on 15 synthetic canine tibiae (SYNBONE AG, Switzerland) using 3D-printed guides. Compression was evaluated using pressure-sensitive films (Prescale, Fujifilm, UK). Three 3.5-mm TPLO plates were tested according to the manufacturer guidelines for dynamic compression screws placement: Synthes, Arthrex, and Biocurve. Each plate was tested five times using a new bone model. The interfragmentary surface was divided into quadrants: Q1 (craniomedial), Q2 (craniolateral), Q3 (caudomedial), and Q4 (caudolateral). Compression was classified as low (0.25 MPa). Significant differences in overall interfragmentary compression were found among the plates (p < 0.001). The Biocurve plate generated the highest and most uniform compression (Q1: 0.285 ± 0.023 MPa; Q2: 0.304 ± 0.010 MPa; Q3: 0.220 ± 0.014 MPa; Q4: 0.237 ± 0.010 MPa). The Arthrex plate produced high compression in Q2 (0.292 ± 0.012 MPa) and moderate in other quadrants (Q1: 0.177 ± 0.016 MPa; Q3: 0.141 ± 0.011 MPa; Q4: 0.189 ± 0.013 MPa). The Synthes plate showed the lowest compression throughout (Q1: 0.050 ± 0.008 MPa; Q2: 0.075 ± 0.009 MPa; Q3: 0.111 ± 0.008 MPa; Q4: 0.109 ± 0.008 MPa). The Biocurve plate, with two angled dynamic compression screw holes, provided the highest, most uniform compression. Further studies are needed to assess clinical relevance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomyBone PlatesTibiaAnimalsDogs

Autor:innen und Institutionen

  • Southern Counties Veterinary Specialists, Hampshire, United Kingdom.
  • Pride Veterinary Referrals, Derby, United Kingdom.

ORCID-Profile: Diogo Miraldo, Rodrigo Alvarez, Maria Zurita

Zitieren

APA

Miraldo, D., Alvarez, R., & Zurita, M. (2026). Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study. Veterinary and Comparative Orthopaedics and Traumatology, 39(01), 047-053. https://doi.org/10.1055/a-2649-9074

Vancouver

Miraldo D, Alvarez R, Zurita M. Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(01):047-053. doi:10.1055/a-2649-9074

BibTeX
@article{Miraldo2026,
  author = {Miraldo, Diogo and Alvarez, Rodrigo and Zurita, Maria},
  title = {Tibial Plateau Leveling Osteotomy Plate Design Influences Interfragmentary Compression: An In Vitro Study},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  volume = {39},
  number = {01},
  pages = {047--053},
  doi = {10.1055/a-2649-9074}
}
Kostenlos starten →