A Review of Non-Invasive Continuous Blood Pressure Measurement: From Flexible Sensing to Intelligent Modeling
AI Sensors · 2025
DOI: 10.3390/aisens1020008 ↗Kurz gefasst
Fachartikel in der Zeitschrift AI Sensors, 2025. Verfasst von Zhan Shen und 6 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 157 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Grants Council of the Hong Kong Special Administrative Region, City University of Hong Kong, Ministry of Science and ICT.
Abstract (Originalsprache)
Accurate and continuous, non-invasive blood pressure (BP) monitoring plays a vital role in the long-term management of cardiovascular diseases. Advances in wearable and flexible sensing technologies have facilitated the transition of non-invasive BP monitoring from clinical settings to ambulatory home environments. However, the measurement consistency and algorithm adaptability of existing devices have not yet reached the level required for routine clinical practice. To address these limitations, comprehensive innovations have been made in material development, sensor design, and algorithm optimization. This review examines the evolution of non-invasive continuous BP measurement, highlighting cutting-edge advances in flexible electronic devices and BP estimation algorithms. First, we introduce measurement principles, sensing devices and limitations of traditional non-invasive BP measurement, including arterial tonometry, arterial volume clamp, and ultrasound-based methods. Subsequently, we review the pulse wave analysis-based BP estimation methods from two perspectives: flexible sensors based on optical, mechanical, and electrical principles, and estimation models that use physiological features or raw waveforms as input. Finally, we conclude the existing challenges and future development directions of flexible electronic technology and intelligent estimation algorithms for non-invasive continuous BP measurement.
Förderung
- Research Grants Council of the Hong Kong Special Administrative Region
- City University of Hong Kong
- Ministry of Science and ICT
Zitieren
APA
Shen, Z., Li, J., Hu, H., Du, C., Ding, X., Pan, T., & Yu, X. (2025). A Review of Non-Invasive Continuous Blood Pressure Measurement: From Flexible Sensing to Intelligent Modeling. AI Sensors. https://doi.org/10.3390/aisens1020008
Vancouver
Shen Z, Li J, Hu H, Du C, Ding X, Pan T, et al. A Review of Non-Invasive Continuous Blood Pressure Measurement: From Flexible Sensing to Intelligent Modeling. AI Sensors. 2025. doi:10.3390/aisens1020008
BibTeX
@article{Shen2025,
author = {Shen, Zhan and Li, Jian and Hu, Hao and Du, Chentao and Ding, Xiaorong and Pan, Tingrui and Yu, Xinge},
title = {A Review of Non-Invasive Continuous Blood Pressure Measurement: From Flexible Sensing to Intelligent Modeling},
journal = {AI Sensors},
year = {2025},
doi = {10.3390/aisens1020008}
}
EUVIMED