EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study

Nastassia Vysotskaya iD, Christoph Will iD, Lorenzo Servadei iD, Noah Maul iD, Christian Mandl, Merlin Nau iD, Jens Harnisch, Andreas Maier iD

Sensors · 19.04.2023 · 23 (8) · 4111

DOI: 10.3390/s23084111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.04.2023. Verfasst von Nastassia Vysotskaya und 7 weiteren Autor:innen. Beteiligte Einrichtung: Infineon Technologies AG, Am Campeon 1-15, 85579 Neubiberg, Germany. Hauptthemen laut MEDLINE: Radar, Blood Pressure Determination. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, German Federal Ministry of Education and Research (BMBF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blood pressure monitoring is of paramount importance in the assessment of a human’s cardiovascular health. The state-of-the-art method remains the usage of an upper-arm cuff sphygmomanometer. However, this device suffers from severe limitations—it only provides a static blood pressure value pair, is incapable of capturing blood pressure variations over time, is inaccurate, and causes discomfort upon use. This work presents a radar-based approach that utilizes the movement of the skin due to artery pulsation to extract pressure waves. From those waves, a set of 21 features was collected and used—together with the calibration parameters of age, gender, height, and weight—as input for a neural network-based regression model. After collecting data from 55 subjects from radar and a blood pressure reference device, we trained 126 networks to analyze the developed approach’s predictive power. As a result, a very shallow network with just two hidden layers produced a systolic error of 9.2±8.3 mmHg (mean error ± standard deviation) and a diastolic error of 7.7±5.7 mmHg. While the trained model did not reach the requirements of the AAMI and BHS blood pressure measuring standards, optimizing network performance was not the goal of the proposed work. Still, the approach has displayed great potential in capturing blood pressure variation with the proposed features. The presented approach therefore shows great potential to be incorporated into wearable devices for continuous blood pressure monitoring for home use or screening applications, after improving this approach even further.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadarBlood Pressure DeterminationHumansBlood PressureFeasibility StudiesSphygmomanometers

Stichwörter der Autor:innen

FMCW radarcontinuous blood pressure monitoringsignal processingvital sensingwearable device

Autor:innen und Institutionen

  • Infineon Technologies AG, Am Campeon 1-15, 85579 Neubiberg, Germany.
  • Department for Computer Science 5 (Pattern Recognition), Friedrich-Alexander-University Erlangen-Nuremberg (FAU), Martensstrasse 3, 91058 Erlangen, Germany.
  • Department of Electrical and Computer Engineering, Technical University of Munich, Arcisstrasse 21, 80333 Munich, Germany.

ORCID-Profile: Nastassia Vysotskaya, Christoph Will, Lorenzo Servadei, Noah Maul, Merlin Nau, Andreas Maier

Förderung

  • Federal Ministry of Education and Research
  • German Federal Ministry of Education and Research (BMBF)

Zitieren

APA

Vysotskaya, N., Will, C., Servadei, L., Maul, N., Mandl, C., Nau, M., Harnisch, J., & Maier, A. (2023). Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study. Sensors, 23(8), 4111. https://doi.org/10.3390/s23084111

Vancouver

Vysotskaya N, Will C, Servadei L, Maul N, Mandl C, Nau M, et al. Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study. Sensors. 2023;23(8):4111. doi:10.3390/s23084111

BibTeX
@article{Vysotskaya2023,
  author = {Vysotskaya, Nastassia and Will, Christoph and Servadei, Lorenzo and Maul, Noah and Mandl, Christian and Nau, Merlin and Harnisch, Jens and Maier, Andreas},
  title = {Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {8},
  pages = {4111},
  doi = {10.3390/s23084111}
}
Kostenlos starten →