EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development and Evaluation of a Low-Cost Device for Environmental Monitoring in Livestock Housing

Charles Paranhos Oliveira, Alex Lopes da Silva, Andre Luiz de Freitas Coelho, Gabriel Machado Dallago, Hemily Rodrigues de Souza, Maria Angela de Souza, Fernanda Campos de Sousa

AgriEngineering · 14.11.2026 · 8 (11) · 489

DOI: 10.3390/agriengineering8110489 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AgriEngineering, online erschienen am 14.11.2026. Verfasst von Charles Paranhos Oliveira und 6 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development, Minas Gerais Research Support Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous monitoring of the thermal environment and air quality in animal production facilities is essential for animal welfare and productive efficiency. The objective was to develop and validate a low-cost device, based on an ESP32 microcontroller and environmental sensors, to measure air temperature, relative humidity, air velocity, ammonia (NH3) and carbon dioxide (CO2) concentrations in compost barn facilities for dairy cattle farming. The device was assembled using low-cost sensors (BME280 for temperature and relative humidity, Wind Sensor Ver. P6 for air velocity, MH-Z19b for CO2 concentration and MQ-137 for NH3 concentration), connected to an ESP32 microcontroller board. The developed devices were calibrated and validated in a climatic chamber (temperature and relative humidity), a flow chamber (CO2 and NH3) and a wind tunnel (air velocity). Their performance was evaluated using the coefficient of determination (R2) and root mean square error (RMSE). Furthermore, the Temperature–Humidity Index (THI) was estimated. Subsequently, the developed devices were tested in a compost barn for seven days to characterize the thermal environment and air quality. The device sensors demonstrated satisfactory performance after individual calibration, with R2 values greater than 0.90 for air temperature, air velocity, and CO2 concentration, and for NH3 ranging from 0.66 to 0.96. The overall RMSE values were 1.01 °C for air temperature, 6.37% for relative humidity, 0.77 m·s−1 for air velocity, 3.43 ppm for NH3, and 203.99 ppm for CO2. The RMSE decomposition showed that the environmental characterization revealed variations in temperature, relative humidity, and gases between the evaluated points, with THI peaks above the thermal stress threshold and an increase in NH3 concentration during bedding turning. The results demonstrate the device’s potential as a tool to support environmental management and the automation of ventilation systems in animal production facilities.

Förderung

  • National Council for Scientific and Technological Development
  • Minas Gerais Research Support Foundation

Zitieren

APA

Oliveira, C. P., Silva, A. L. D., Coelho, A. L. D. F., Dallago, G. M., Souza, H. R. D., Souza, M. A. D., & Sousa, F. C. D. (2026). Development and Evaluation of a Low-Cost Device for Environmental Monitoring in Livestock Housing. AgriEngineering, 8(11), 489. https://doi.org/10.3390/agriengineering8110489

Vancouver

Oliveira CP, Silva ALD, Coelho ALDF, Dallago GM, Souza HRD, Souza MAD, et al. Development and Evaluation of a Low-Cost Device for Environmental Monitoring in Livestock Housing. AgriEngineering. 2026;8(11):489. doi:10.3390/agriengineering8110489

BibTeX
@article{Oliveira2026,
  author = {Oliveira, Charles Paranhos and Silva, Alex Lopes da and Coelho, Andre Luiz de Freitas and Dallago, Gabriel Machado and Souza, Hemily Rodrigues de and Souza, Maria Angela de and Sousa, Fernanda Campos de},
  title = {Development and Evaluation of a Low-Cost Device for Environmental Monitoring in Livestock Housing},
  journal = {AgriEngineering},
  year = {2026},
  volume = {8},
  number = {11},
  pages = {489},
  doi = {10.3390/agriengineering8110489}
}