Design, Development, and Validation of a Low-Cost Power Harmonic Monitoring Device for LED Lighting Systems
Engineering, Technology & Applied Science Research · 11.08.2026 · 16 (4) · 38513-38524
DOI: 10.48084/etasr.16821 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering, Technology & Applied Science Research, online erschienen am 11.08.2026. Verfasst von Paul John Infante und 1 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Light Emitting Diodes (LEDs) are a modern lighting technology that can reduce energy consumption by 70-85% compared with conventional lighting technologies. However, an LED is a nonlinear load that generates harmonic distortions. Large-scale LED installations in buildings can cause significant power quality issues. The purpose of the present study is to design and develop a low-cost power harmonic monitoring device for LEDs. The comparison of the Fluke 1736 power logger with a prototype utilizing a low-cost ESP32 microcontroller and current and voltage sensors involved an experimental setup comprising a single LED and 18 LED tubes operated in a low-voltage (LV) single-phase 60 Hz network. The Total Harmonic Distortion (THD) measurement method was applied, and the results were validated against specific IEC standards. It was observed that with a supply voltage of 236.3V, the single FSL T8 18 W LED lamp consumed 16.87 W and drawn 0.14 A, with 0.51 Power Factor (PF), 94.7% Total Current Harmonic Distortion (THDi), and 1.5% Total Voltage Harmonic Distortion (THDv). For 18 tube LEDs, at a supply voltage of 242.7 V, 296.4 W power was consumed, and 2.2 A current was measured, with 0.56 PF, 133.8% THDi, and 1.7% THDv. The absolute error of the prototype was ±0.24V and ±0.02A, with THDi and THDv at ±0.08% and ±0.02%, respectively, which are acceptable error limits according to the International Electrotechnical Commission (IEC) standards for low-cost instrumentation Class S. The findings showed that the FSL T8 18 W LED had a poor PF and a high THD content. The current harmonic distortion was related to the number of LED installations. This study revealed the significance of monitoring the power harmonics of modern lighting technology, which can be achieved using a low-cost power harmonic monitoring device.
Zitieren
APA
Infante, P. J., & Querikiol, E. (2026). Design, Development, and Validation of a Low-Cost Power Harmonic Monitoring Device for LED Lighting Systems. Engineering, Technology & Applied Science Research, 16(4), 38513-38524. https://doi.org/10.48084/etasr.16821
Vancouver
Infante PJ, Querikiol E. Design, Development, and Validation of a Low-Cost Power Harmonic Monitoring Device for LED Lighting Systems. Engineering, Technology & Applied Science Research. 2026;16(4):38513-38524. doi:10.48084/etasr.16821
BibTeX
@article{Infante2026,
author = {Infante, Paul John and Querikiol, Edward},
title = {Design, Development, and Validation of a Low-Cost Power Harmonic Monitoring Device for LED Lighting Systems},
journal = {Engineering, Technology & Applied Science Research},
year = {2026},
volume = {16},
number = {4},
pages = {38513--38524},
doi = {10.48084/etasr.16821}
}
EUVIMED