Polymerization of a resin composite luting agent: effects of temperature, preheating duration, and light-curing duration
Frontiers in Oral Health · 09.07.2026 · 7
DOI: 10.3389/froh.2026.1881185 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oral Health, online erschienen am 09.07.2026. Verfasst von Ahmad Alsahli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Dental Practice, College of Dentistry, Kuwait University, Safat, Kuwait. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kuwait University.
Abstract (Originalsprache)
Objective
This study evaluated how preheating temperature and duration, and light-curing time affect the microhardness (HV) and degree of conversion (DC) of a preheated resin composite used as a luting agent. Materials and methods A microhybrid composite was preheated to 54 °C or 68 °C for 5, 10, or 15 min, and then placed between a 4.0 mm lithium disilicate overlay and a natural tooth as a luting agent. Light-curing was performed for 120, 180, or 270 s. The microhardness and degree of conversion were measured. Three-way ANOVA analyzed the effects and interactions of the variables. Pearson's correlation assessed the relationship between HV and DC.
Results
DC was not significantly affected by preheating temperature, duration, or light-curing time ( p > 0.05). HV was significantly influenced by all variables ( p ≤ 0.001), with the highest HV at 68 °C for 15 min and longer curing. A significant three-way interaction was noted ( p = 0.039). No consistent correlation was found between DC and HV, except for one condition (54 °C, 5 min, 90 s; ρ = 0.97, p = 0.005).
Conclusions
Within the preheating conditions evaluated, higher preheating temperatures, longer preheating durations, and extended curing times were associated with increased microhardness, but not the degree of conversion, of the resin composite under ceramic restorations. Clinical significance Among the preheating protocols evaluated, higher preheating temperatures, longer preheating durations, and extended multidirectional light-curing times were associated with higher microhardness of resin composites used as luting agents beneath thick (4 mm) lithium disilicate restorations, without affecting the degree of conversion. Because no non-preheated control group was included, these findings should be interpreted as comparisons among different preheating protocols rather than evidence of the benefits of preheating itself. Furthermore, the extended curing times investigated in this study represent optimal experimental conditions for the evaluated restoration configuration and may not always be practical or feasible in routine clinical settings. Minimizing the delay between preheating and curing may help preserve the effects associated with the investigated preheating protocols.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Dental Practice, College of Dentistry, Kuwait University, Safat, Kuwait.
- Department of Bioclinical Sciences, College of Dentistry, Kuwait University, Safat, Kuwait.
- Ministry of Health, Safat, Kuwait.
- Department of Restorative Sciences, College of Dentistry, Kuwait University, Safat, Kuwait.
Förderung
- Kuwait University
Zitieren
APA
Alsahli, A., Qasim, S. S. B., AlMatar, D., AlSanousi, S., & Baig, M. R. (2026). Polymerization of a resin composite luting agent: effects of temperature, preheating duration, and light-curing duration. Frontiers in Oral Health, 7. https://doi.org/10.3389/froh.2026.1881185
Vancouver
Alsahli A, Qasim SSB, AlMatar D, AlSanousi S, Baig MR. Polymerization of a resin composite luting agent: effects of temperature, preheating duration, and light-curing duration. Frontiers in Oral Health. 2026;7. doi:10.3389/froh.2026.1881185
BibTeX
@article{Alsahli2026,
author = {Alsahli, Ahmad and Qasim, Syed Saad B and AlMatar, Dalal and AlSanousi, Shaikha and Baig, Mirza Rustum},
title = {Polymerization of a resin composite luting agent: effects of temperature, preheating duration, and light-curing duration},
journal = {Frontiers in Oral Health},
year = {2026},
volume = {7},
doi = {10.3389/froh.2026.1881185}
}
EUVIMED