Biomechanical evaluation of narrow-diameter Ti–Zr implant systems at different lingual inclination angles in the molar region

Lishan Li, Zhe Chen, Jinchuan Zheng, Hang Lin, Wenbeng Xie

Frontiers in Oral Health · 06.07.2026 · 7

DOI: 10.3389/froh.2026.1878801 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oral Health, online erschienen am 06.07.2026. Verfasst von Lishan Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: People's Hospital Affiliated of Quanzhou Medical College, Fujian, China. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Narrow-diameter implants may be considered in posterior sites with limited bone volume, while lingual inclination may help avoid anatomical constraints. However, their biomechanical behavior under different loading directions remains unclear.

Objective

To compare the system-level biomechanical responses of a 3.3 × 12 mm titanium–zirconium implant configuration and a 4.1 × 10 mm commercially pure titanium implant configuration at different lingual inclination angles.

Methods

Three-dimensional finite element models were constructed for both implant systems at 0°, 5°, 10°, 15°, and 20°. A 150 N vertical load and a 150 N load applied at 30° to the prosthetic crown axis were simulated. Implant von Mises stress and cortical and cancellous bone maximum principal stress were evaluated. Formal mesh convergence analysis was performed using three mesh densities. Exploratory fatigue analysis and in vitro displacement testing were conducted under vertical loading.

Results

Mesh convergence showed less than 5% change between the medium and fine meshes for all primary stress outcomes. Under vertical loading, implant stress decreased from 0° to 10° and then showed modest fluctuations. Oblique loading increased implant and peri-implant bone stresses in all configurations, with generally greater amplification at larger inclination angles. Implant stress remained lower at 10° than at 0° under both loading conditions, whereas cortical bone stress increased across the same range. In vitro displacement remained relatively stable from 0° to 10° and increased at 15° and 20°.

Conclusions

Inclination-related responses depended on loading direction and the evaluated biomechanical outcome. The 0°–10° range should not be interpreted as uniformly favorable or clinically recommended. Because the systems differed in material, diameter, length, and geometry, the findings represent system-level comparisons.

Schlagwörter

Stichwörter der Autor:innen

in-vitro experimentinclined implantationmolar regionnarrow-diameter implantoblique loadingthree-dimensional finite element analysistitanium–zirconium alloy

Autor:innen und Institutionen

  • People's Hospital Affiliated of Quanzhou Medical College, Fujian, China.
  • Department of Oromaxillofacial Head and Neck Surgery, Center for Oromaxillofacial Head and Neck Disorders, Huashan Hospital, Fudan University, Shanghai, China.
  • Department of Oral Maxillo-Facial Surgery, the First Affiliated Hospital, Fujian Medical University, Fuzhou, China.

Zitieren

APA

Li, L., Chen, Z., Zheng, J., Lin, H., & Xie, W. (2026). Biomechanical evaluation of narrow-diameter Ti–Zr implant systems at different lingual inclination angles in the molar region. Frontiers in Oral Health, 7. https://doi.org/10.3389/froh.2026.1878801

Vancouver

Li L, Chen Z, Zheng J, Lin H, Xie W. Biomechanical evaluation of narrow-diameter Ti–Zr implant systems at different lingual inclination angles in the molar region. Frontiers in Oral Health. 2026;7. doi:10.3389/froh.2026.1878801

BibTeX
@article{Li2026,
  author = {Li, Lishan and Chen, Zhe and Zheng, Jinchuan and Lin, Hang and Xie, Wenbeng},
  title = {Biomechanical evaluation of narrow-diameter Ti–Zr implant systems at different lingual inclination angles in the molar region},
  journal = {Frontiers in Oral Health},
  year = {2026},
  volume = {7},
  doi = {10.3389/froh.2026.1878801}
}
Kostenlos starten →