EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Different Degrees of lingual Implant Inclination on the Retention of Locator Retained Mandibular Implant Overdenture. An In-Vitro Study

Ruba Shuayb, Mohamed Abokrais

Libyan Journal of Medical Research · 01.01.2024 · 18 (1) · 205-213

DOI: 10.54361/ljmr18-1.20 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Libyan Journal of Medical Research, online erschienen am 01.01.2024. Verfasst von Ruba Shuayb und 1 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study was condacted to evaluate and compare different degrees of lingual implant inclination on retention of locator attachments used for two implant retained mandibular overdentures .Materials and Methods: Four acrylic resin models representing acompletely edentulous mandibular ridges were used. Each model received two implants inserted at canine area bilaterally with different degree of lingual inclination. Group I (control Group) 00, Group II (100), Group III (200), and Group IV (300). The residual ridge and the retromlar regions for each acrylic resin model were covered by auto-polymerized silicon material to simulate the oral mucosa. Four experimental acrylic metal reinforced overdenture were fabricated and connected to the implants using Locator attachments, Universal Testing Machine was used for measuring initial and final retentive force, The Results: Locator transparent, 00 inclination and anterior dislodging recorded the highest retentive forces, while Locator blue 100 inclination and vertical dislodging recorded the lowest retention values.

Conclusions

For majority of groups, inserts, dislodging forces, initial retention recorded significant higher values than final retention.

Zitieren

APA

Shuayb, R., & Abokrais, M. (2024). Effect of Different Degrees of lingual Implant Inclination on the Retention of Locator Retained Mandibular Implant Overdenture. An In-Vitro Study. Libyan Journal of Medical Research, 18(1), 205-213. https://doi.org/10.54361/ljmr18-1.20

Vancouver

Shuayb R, Abokrais M. Effect of Different Degrees of lingual Implant Inclination on the Retention of Locator Retained Mandibular Implant Overdenture. An In-Vitro Study. Libyan Journal of Medical Research. 2024;18(1):205-213. doi:10.54361/ljmr18-1.20

BibTeX
@article{Shuayb2024,
  author = {Shuayb, Ruba and Abokrais, Mohamed},
  title = {Effect of Different Degrees of lingual Implant Inclination on the Retention of Locator Retained Mandibular Implant Overdenture. An In-Vitro Study},
  journal = {Libyan Journal of Medical Research},
  year = {2024},
  volume = {18},
  number = {1},
  pages = {205--213},
  doi = {10.54361/ljmr18-1.20}
}
Kostenlos starten →