EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals

Baogen Huang, Feng Wang, Jing Li, Suping Sun, Huiying Lv, Lu Lu, Quan Shi, Chenchen Ding, Yiping Mao

Frontiers in Public Health · 22.06.2026 · 13

DOI: 10.3389/fpubh.2025.1700856 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Public Health, online erschienen am 22.06.2026. Verfasst von Baogen Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Fengxian People's Hospital, Xuzhou, Jiangsu, China. Hauptthemen laut MEDLINE: Disinfection, Ultraviolet Rays, Cross Infection. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the disinfection efficacy of a third-generation gallium nitride (GaN)-based deep ultraviolet (UVC) LED disinfection cabinet on often-touch surfaces of small advanced electronic devices in hospital clinical environments, and to provide evidence for its application in hospital infection control.

Methods

A total of 329 device surfaces from 10 randomly selected departments were sampled: 66 computer mice, 151 mobile phones, 53 Personal Digital Assistants (PDAs), 29 electronic glucometers, and 30 electronic sphygmomanometers. Pre-disinfection bacterial contamination levels were assessed. The UVC-LED cabinet was used for disinfection (10-min cycle, 24 mJ/cm 2 dose), and a natural bacteria eradication test was conducted.

Results

A total of 658 sampling points (329 pre- and post-disinfection) were monitored. Before disinfection, 57.1% of device surfaces showed microbial contamination, with mice and cleaning staff's mobile phones exhibiting relatively severe bacterial contamination. After disinfection, 97.9% of device surfaces showed bacterial colony counts reduced to 0 CFU, with an average natural bacteria eradication rate of 99.9% (range ≥90%).

Conclusion

High-frequency use of small advanced electronic devices by healthcare workers poses hospital infection risks. Deep LED Ultraviolet-C disinfection effectively reduces microbial load on surfaces of devices incompatible with chemical disinfectants or heat. It is recommended as a routine disinfection measure for hospital infection control. This study demonstrates high efficacy under controlled conditions; however, real-world effectiveness may be influenced by factors such as device positioning and surface shadows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DisinfectionUltraviolet RaysCross InfectionHumansHospitalsEquipment Contamination

Stichwörter der Autor:innen

Deep LED Ultraviolet-Cdisinfection efficacyhospital infection controlhospital often-touch surfacesnatural microbiota

Autor:innen und Institutionen

  • Fengxian People's Hospital, Xuzhou, Jiangsu, China.
  • The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.

Zitieren

APA

Huang, B., Wang, F., Li, J., Sun, S., Lv, H., Lu, L., Shi, Q., Ding, C., & Mao, Y. (2026). Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals. Frontiers in Public Health, 13. https://doi.org/10.3389/fpubh.2025.1700856

Vancouver

Huang B, Wang F, Li J, Sun S, Lv H, Lu L, et al. Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals. Frontiers in Public Health. 2026;13. doi:10.3389/fpubh.2025.1700856

BibTeX
@article{Huang2026,
  author = {Huang, Baogen and Wang, Feng and Li, Jing and Sun, Suping and Lv, Huiying and Lu, Lu and Shi, Quan and Ding, Chenchen and Mao, Yiping},
  title = {Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals},
  journal = {Frontiers in Public Health},
  year = {2026},
  volume = {13},
  doi = {10.3389/fpubh.2025.1700856}
}
Kostenlos starten →