The efficacy of a filtered handheld far-ultraviolet disinfection device for decontamination of high-touch surfaces in healthcare settings: a genomic bacterial analysis

Layale Yaghi iD, Roy F Chemaly, Rita Wilson-Dib, William C Shropshire iD, Sherry Cantu, Micah Bhatti, Piyali Chatterjee iD, Chetan Jinadatha, Amy Spallone iD

Infection Control & Hospital Epidemiology · 2025-10 · 46 (10) · 1027-1034

DOI: 10.1017/ice.2025.10251 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, online erschienen am 05.09.2025. Verfasst von Layale Yaghi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Diseases, Infection Control and Employee Health, The University of Texas MD Anderson Cancer Center, Houston, TX, USA. Hauptthemen laut MEDLINE: Disinfection, Cross Infection, Decontamination, Ultraviolet Rays. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and objectives: Enhanced environmental disinfection is linked to reduced hospital-acquired infection rates. In this study, we aimed to evaluate the efficacy of an emerging disinfection technology, a filtered far-UV-C handheld (FFUHH) device, for reducing bacterial loads on high-touch surfaces in shared clinical workrooms, and to isolate, identify and characterize clinically significant environmental pathogens.

Methods

We compared samples from high-touch items (dictation device, mouse, armchair, desk, and keyboard) before and after FFUHH treatment. Samples were collected weekly: contact plates for colony counts and swabs before and after intervention on standardized adjacent areas for each surface, respectively. The swabs were enriched and cultured on selective media to isolate pathogens. Environmental samples, as well as clinical samples collected from patients during the study period, were validated using MALDI-TOF and whole genome sequencing.

Results

Among the 440 collected plates (220 before and 220 after treatment), the highest mean colony count pre-treatment was detected from armchairs, and the lowest from keyboards. The mean reduction of colony-forming units ranged 53% and 83% and was statistically significant ( P < 0.05) across all surfaces except for the keyboard. We characterized multidrug-resistant Staphylococcus epidermidis ST5 and ST16 strains, a carbapenem-resistant Acinetobacter baumannii, and a Klebsiella pneumoniae genetically related to a clinical isolate with a rare sequence type not previously detected in our institution.

Conclusion

The FFUHH effectively reduced the microbial burden on high-touch surfaces. It can offer an advantage for surface disinfection and an alternative to routinely used biocides.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DisinfectionCross InfectionDecontaminationUltraviolet RaysHumansBacterial LoadColony Count, MicrobialAcinetobacter baumanniiEquipment Contamination

Autor:innen und Institutionen

  • Department of Infectious Diseases, Infection Control and Employee Health, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
  • The University of Oklahoma College of Medicine, Oklahoma City, OK, USA.
  • Department of Infection Control, Chief Quality Office, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
  • Department of Laboratory Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
  • Department of Medical Education, College of Medicine, Texas A&M University, Bryan, TX, USA.
  • Department of Medicine, Central Texas Veterans Health Care System, Temple, TX, USA.

ORCID-Profile: Layale Yaghi, William C Shropshire, Piyali Chatterjee, Amy Spallone

Zitieren

APA

Yaghi, L., Chemaly, R. F., Wilson-Dib, R., Shropshire, W. C., Cantu, S., Bhatti, M., Chatterjee, P., Jinadatha, C., & Spallone, A. (2025). The efficacy of a filtered handheld far-ultraviolet disinfection device for decontamination of high-touch surfaces in healthcare settings: a genomic bacterial analysis. Infection Control & Hospital Epidemiology, 46(10), 1027-1034. https://doi.org/10.1017/ice.2025.10251

Vancouver

Yaghi L, Chemaly RF, Wilson-Dib R, Shropshire WC, Cantu S, Bhatti M, et al. The efficacy of a filtered handheld far-ultraviolet disinfection device for decontamination of high-touch surfaces in healthcare settings: a genomic bacterial analysis. Infection Control & Hospital Epidemiology. 2025;46(10):1027-1034. doi:10.1017/ice.2025.10251

BibTeX
@article{Yaghi2025,
  author = {Yaghi, Layale and Chemaly, Roy F and Wilson-Dib, Rita and Shropshire, William C and Cantu, Sherry and Bhatti, Micah and Chatterjee, Piyali and Jinadatha, Chetan and Spallone, Amy},
  title = {The efficacy of a filtered handheld far-ultraviolet disinfection device for decontamination of high-touch surfaces in healthcare settings: a genomic bacterial analysis},
  journal = {Infection Control & Hospital Epidemiology},
  year = {2025},
  volume = {46},
  number = {10},
  pages = {1027--1034},
  doi = {10.1017/ice.2025.10251}
}
Kostenlos starten →