Catheter spatial configuration and biological factors predict fibrin sheath–related dysfunction in totally implantable venous access ports
Frontiers in Oncology · 02.11.2026 · 16
DOI: 10.3389/fonc.2026.1990440 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 02.11.2026. Verfasst von Chenkai Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional and Vascular Surgery, Affiliated Hospital of Nantong University, Nantong, China. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Fibrin sheath formation is a major cause of totally implantable venous access port (TIVAP) dysfunction, but tools for early risk assessment remain limited.
Objectives
To develop and validate an interpretable model for early post-implantation risk stratification and explore the hemodynamic context of catheter spatial predictors.
Methods
This single-center retrospective study included 507 patients divided into training, internal testing, and temporal validation cohorts. Demographic, laboratory, and catheter spatial variables were assessed. Nine predictors were selected using univariable logistic regression, Boruta, and least absolute shrinkage and selection operator (LASSO) regression. Eight machine-learning models were compared for discrimination, calibration, and clinical utility. The final model was interpreted using SHapley Additive Explanations (SHAP), and computational fluid dynamics (CFD) was performed in representative cases.
Results
XGBoost-linear showed stable discrimination, with areas under the curve of 0.891 in the internal testing cohort and 0.904 in the temporal validation cohort. SHAP analysis identified catheter spatial parameters as the leading predictors, while coagulation and inflammatory indices provided complementary information. In the two representative cases, hemodynamic disturbances were observed near venous curvature, confluence, and catheter–wall contact regions, with heterogeneous wall-based indices in the lower superior vena cava (SVC) above the right atrium (RA). A simplified six-variable model retained comparable performance in temporal validation (area under the curve, 0.893) and was implemented as an interactive web-based tool.
Conclusion
The model may support interpretable early risk stratification and closer catheter-function monitoring, subject to prospective multicenter validation. Exploratory CFD analysis in two representative cases provided preliminary hemodynamic context for the model-identified spatial predictors.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional and Vascular Surgery, Affiliated Hospital of Nantong University, Nantong, China.
- Medical School, Nantong University, Nantong, China.
Zitieren
APA
Wu, C., Zong, Y., Bao, Y., Yang, X., Zhao, H., Chen, C., Zhao, S., & Gu, W. (2026). Catheter spatial configuration and biological factors predict fibrin sheath–related dysfunction in totally implantable venous access ports. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1990440
Vancouver
Wu C, Zong Y, Bao Y, Yang X, Zhao H, Chen C, et al. Catheter spatial configuration and biological factors predict fibrin sheath–related dysfunction in totally implantable venous access ports. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1990440
BibTeX