Ultrasound measurement of skin-to-septum distance in totally implantable venous access ports: Considerations for Huber needle length
The Journal of Vascular Access · 2026-11 · 27 (6) · 2797-2803
DOI: 10.1177/11297298261472621 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 18.08.2026. Verfasst von Mari Abe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute for Next-Generation Nursing Education, Tokyo, Japan. Die Arbeit nennt 12 Literaturangaben. Gefördert von: Terumo Foundation for Life Sciences and Arts.
Abstract (Originalsprache)
Background
Objective criteria for selecting Huber needle length for totally implantable venous access ports (TIVAPs) are limited. This study primarily described skin-to-septum distance using ultrasonography and its correlation with body habitus.
Methods
Thirty-three patients with TIVAPs for chemotherapy were included. Skin-to-septum distance was measured by ultrasonography in two positions: supine with arms at the sides and with shoulder flexion. Pearson’s correlation coefficient assessed correlation between body mass index (BMI) and septal depth. Excess needle length beyond the port base was calculated.
Results
Mean skin-to-septum distance was 1.7 ± 0.4 mm (arms at sides) and 1.8 ± 0.5 mm (shoulder flexion). A 16-mm Huber needle was used in 97.0%. The median excess needle length was 2.4 mm. BMI showed weak correlation with septal depth ( r = 0.33, p = 0.062).
Conclusions
Septal depth was shallow, and BMI alone was not a reliable predictor. Ultrasound may support Huber needle selection.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Institute for Next-Generation Nursing Education, Tokyo, Japan.
- Department of Nursing, The University of Tokyo Hospital, Tokyo, Japan.
- Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
- UTokyo Nursing Dissemination and Implementation Science Institute, Tokyo, Japan.
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan.
- Department of Chemotherapy, The University of Tokyo Hospital, Tokyo, Japan.
ORCID-Profile: Mari Abe, Takatoshi Kubo, Hikaru Haruki, Hironori Ishigami, Gojiro Nakagami
Förderung
- Terumo Foundation for Life Sciences and Arts
Zitieren
APA
Abe, M., Kubo, T., Haruki, H., Ishigami, H., Ishigaki, K., Suzuki, A., & Nakagami, G. (2026). Ultrasound measurement of skin-to-septum distance in totally implantable venous access ports: Considerations for Huber needle length. The Journal of Vascular Access, 27(6), 2797-2803. https://doi.org/10.1177/11297298261472621
Vancouver
Abe M, Kubo T, Haruki H, Ishigami H, Ishigaki K, Suzuki A, et al. Ultrasound measurement of skin-to-septum distance in totally implantable venous access ports: Considerations for Huber needle length. The Journal of Vascular Access. 2026;27(6):2797-2803. doi:10.1177/11297298261472621
BibTeX
@article{Abe2026,
author = {Abe, Mari and Kubo, Takatoshi and Haruki, Hikaru and Ishigami, Hironori and Ishigaki, Kazunaga and Suzuki, Ayako and Nakagami, Gojiro},
title = {Ultrasound measurement of skin-to-septum distance in totally implantable venous access ports: Considerations for Huber needle length},
journal = {The Journal of Vascular Access},
year = {2026},
volume = {27},
number = {6},
pages = {2797--2803},
doi = {10.1177/11297298261472621}
}
EUVIMED