EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study

Alparslan Serarslan, Rana Elif Yıldız, Telat Aksu, Nilgün Özbek Okumuş, Deniz Meydan, Bilge Gürsel

Frontiers in Oncology · 05.08.2026 · 16

DOI: 10.3389/fonc.2026.1901196 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 05.08.2026. Verfasst von Alparslan Serarslan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Türkiye. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study evaluated a dual-optimization strategy for single-isocenter multiple-target stereotactic radiosurgery (SIMT-SRS) in patients with multiple brain metastases, combining target-anchored isocenter placement with individualized dose prescription for each planning target volume (PTV).

Methods

Three volumetric modulated arc therapy-based SIMT-SRS planning techniques were compared in 22 patients harboring 5–10 brain metastases: geometric center isocenter with composite dose prescription (GCI-Comp), target-anchored isocenter with composite dose prescription (TAI-Comp), and target-anchored isocenter with individual dose prescription (TAI-Ind). Dosimetric parameters for PTVs and organs at risk (OARs) were extracted and compared using the Friedman test followed by Bonferroni-corrected post hoc analyses.

Results

All three techniques achieved equivalent target coverage (V95% > 99%, p = 0.202), plan quality (Q RTOG , p = 0.385), and conformity (CI Paddick , p = 0.546). Compared to GCI-Comp and TAI-Comp, TAI-Ind produced significantly higher intratumoral dose escalation (PTV–D max : 2025.60 vs. 2113.80 vs. 2241.34 cGy, p < 0.001) while achieving a significantly steeper dose gradient (R 50% : 13.43 vs. 12.07 vs. 10.31; GI Paddick : 12.91 vs. 12.10 vs. 9.41; both p < 0.001). TAI-Ind also resulted in the lowest normal brain dose exposure (V12Gy: 35.53 cm 3 ; D 50% : 322.36 cGy) and significantly reduced maximum doses to the hippocampus, brainstem, spinal canal, and bilateral cochleae (all p < 0.001). These dosimetric advantages were achieved at the expense of requiring a higher number of monitor units (6013.84 vs. 6494.89 vs. 7268.92, p < 0.001).

Conclusions

The TAI-Ind dual-optimization strategy provided greater intratumoral dose escalation and more favorable OARs sparing compared with the composite-prescription techniques, without compromising target coverage. This approach represents a promising strategy for SIMT-SRS planning in patients with multiple brain metastases, warranting further clinical validation.

Schlagwörter

Stichwörter der Autor:innen

brain metastasescomputer-assisted radiotherapy planninglinac radiosurgeryradiation dosimetryradiotherapystereotactic radiation therapystereotactic radiosurgeryvolumetric modulated arc therapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Türkiye.

Zitieren

APA

Serarslan, A., Yıldız, R. E., Aksu, T., Özbek Okumuş, N., Meydan, D., & Gürsel, B. (2026). Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1901196

Vancouver

Serarslan A, Yıldız RE, Aksu T, Özbek Okumuş N, Meydan D, Gürsel B. Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1901196

BibTeX
@article{Serarslan2026,
  author = {Serarslan, Alparslan and Yıldız, Rana Elif and Aksu, Telat and Özbek Okumuş, Nilgün and Meydan, Deniz and Gürsel, Bilge},
  title = {Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study},
  journal = {Frontiers in Oncology},
  year = {2026},
  volume = {16},
  doi = {10.3389/fonc.2026.1901196}
}
Kostenlos starten →