Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study
Frontiers in Oncology · 05.08.2026 · 16
DOI: 10.3389/fonc.2026.1901196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 05.08.2026. Verfasst von Alparslan Serarslan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Türkiye. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
This study evaluated a dual-optimization strategy for single-isocenter multiple-target stereotactic radiosurgery (SIMT-SRS) in patients with multiple brain metastases, combining target-anchored isocenter placement with individualized dose prescription for each planning target volume (PTV).
Methods
Three volumetric modulated arc therapy-based SIMT-SRS planning techniques were compared in 22 patients harboring 5–10 brain metastases: geometric center isocenter with composite dose prescription (GCI-Comp), target-anchored isocenter with composite dose prescription (TAI-Comp), and target-anchored isocenter with individual dose prescription (TAI-Ind). Dosimetric parameters for PTVs and organs at risk (OARs) were extracted and compared using the Friedman test followed by Bonferroni-corrected post hoc analyses.
Results
All three techniques achieved equivalent target coverage (V95% > 99%, p = 0.202), plan quality (Q RTOG , p = 0.385), and conformity (CI Paddick , p = 0.546). Compared to GCI-Comp and TAI-Comp, TAI-Ind produced significantly higher intratumoral dose escalation (PTV–D max : 2025.60 vs. 2113.80 vs. 2241.34 cGy, p < 0.001) while achieving a significantly steeper dose gradient (R 50% : 13.43 vs. 12.07 vs. 10.31; GI Paddick : 12.91 vs. 12.10 vs. 9.41; both p < 0.001). TAI-Ind also resulted in the lowest normal brain dose exposure (V12Gy: 35.53 cm 3 ; D 50% : 322.36 cGy) and significantly reduced maximum doses to the hippocampus, brainstem, spinal canal, and bilateral cochleae (all p < 0.001). These dosimetric advantages were achieved at the expense of requiring a higher number of monitor units (6013.84 vs. 6494.89 vs. 7268.92, p < 0.001).
Conclusions
The TAI-Ind dual-optimization strategy provided greater intratumoral dose escalation and more favorable OARs sparing compared with the composite-prescription techniques, without compromising target coverage. This approach represents a promising strategy for SIMT-SRS planning in patients with multiple brain metastases, warranting further clinical validation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Türkiye.
Zitieren
APA
Serarslan, A., Yıldız, R. E., Aksu, T., Özbek Okumuş, N., Meydan, D., & Gürsel, B. (2026). Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1901196
Vancouver
Serarslan A, Yıldız RE, Aksu T, Özbek Okumuş N, Meydan D, Gürsel B. Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1901196
BibTeX
@article{Serarslan2026,
author = {Serarslan, Alparslan and Yıldız, Rana Elif and Aksu, Telat and Özbek Okumuş, Nilgün and Meydan, Deniz and Gürsel, Bilge},
title = {Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study},
journal = {Frontiers in Oncology},
year = {2026},
volume = {16},
doi = {10.3389/fonc.2026.1901196}
}
EUVIMED