Automating the treatment planning process for 3D‐conformal pediatric craniospinal irradiation therapy

Soleil Hernandez iD, Callistus Nguyen iD, Jeannette Parkes iD, Hester Burger, Dong Joo Rhee, Tucker Netherton, Raymond Mumme iD, Jean Gumma-De La Vega, Jack Duryea, Alexandrea Leone, Arnold C Paulino iD, Carlos Cardenas und 4 weitere

Pediatric Blood & Cancer · 2023-03 · 70 (3)

DOI: 10.1002/pbc.30164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Blood & Cancer, online erschienen am 02.01.2023. Verfasst von Soleil Hernandez und 15 weiteren Autor:innen. Beteiligte Einrichtung: The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA. Hauptthemen laut MEDLINE: Medulloblastoma, Craniospinal Irradiation, Radiotherapy, Conformal, Cerebellar Neoplasms. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Pediatric patients with medulloblastoma in low‐ and middle‐income countries (LMICs) are most treated with 3D‐conformal photon craniospinal irradiation (CSI), a time‐consuming, complex treatment to plan, especially in resource‐constrained settings. Therefore, we developed and tested a 3D‐conformal CSI autoplanning tool for varying patient lengths. Methods and materials Autocontours were generated with a deep learning model trained:tested (80:20 ratio) on 143 pediatric medulloblastoma CT scans (patient ages: 2–19 years, median = 7 years). Using the verified autocontours, the autoplanning tool generated two lateral brain fields matched to a single spine field, an extended single spine field, or two matched spine fields. Additional spine subfields were added to optimize the corresponding dose distribution. Feathering was implemented (yielding nine to 12 fields) to give a composite plan. Each planning approach was tested on six patients (ages 3–10 years). A pediatric radiation oncologist assessed clinical acceptability of each autoplan.

Results

The autocontoured structures’ average Dice similarity coefficient ranged from .65 to .98. The average V95 for the brain/spinal canal for single, extended, and multi‐field spine configurations was 99.9% ± 0.06%/99.9% ± 0.10%, 99.9% ± 0.07%/99.4% ± 0.30%, and 99.9% ± 0.06%/99.4% ± 0.40%, respectively. The average maximum dose across all field configurations to the brainstem, eyes (L/R), lenses (L/R), and spinal cord were 23.7 ± 0.08, 24.1 ± 0.28, 13.3 ± 5.27, and 25.5 ± 0.34 Gy, respectively (prescription = 23.4 Gy/13 fractions). Of the 18 plans tested, all were scored as clinically acceptable as‐is or clinically acceptable with minor, time‐efficient edits preferred or required. No plans were scored as clinically unacceptable.

Conclusion

The autoplanning tool successfully generated pediatric CSI plans for varying patient lengths in 3.50 ± 0.4 minutes on average, indicating potential for an efficient planning aid in a resource‐constrained settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MedulloblastomaCraniospinal IrradiationRadiotherapy, ConformalCerebellar NeoplasmsHumansChildChild, PreschoolAdolescentYoung AdultAdultRadiotherapy Planning, Computer-AssistedRadiotherapy Dosage

Stichwörter der Autor:innen

automated contouringautomated treatment planningcraniospinal irradiation therapyglobal radiation therapy accesspediatric medulloblastoma

Autor:innen und Institutionen

  • The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.
  • Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Radiation Oncology, Groote Schuur Hospital and University of Cape Town, Cape Town, South Africa.
  • Department Medical Physics, Groote Schuur Hospital and University of Cape Town, Cape Town, South Africa.
  • Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.

ORCID-Profile: Soleil Hernandez, Callistus Nguyen, Jeannette Parkes, Raymond Mumme, Arnold C Paulino

Zitieren

APA

Hernandez, S., Nguyen, C., Parkes, J., Burger, H., Rhee, D. J., Netherton, T., Mumme, R., Vega, J. G., Duryea, J., Leone, A., Paulino, A. C., Cardenas, C., Howell, R., Fuentes, D., Pollard-Larkin, J., & Court, L. (2023). Automating the treatment planning process for 3D‐conformal pediatric craniospinal irradiation therapy. Pediatric Blood & Cancer, 70(3). https://doi.org/10.1002/pbc.30164

Vancouver

Hernandez S, Nguyen C, Parkes J, Burger H, Rhee DJ, Netherton T, et al. Automating the treatment planning process for 3D‐conformal pediatric craniospinal irradiation therapy. Pediatric Blood & Cancer. 2023;70(3). doi:10.1002/pbc.30164

BibTeX
@article{Hernandez2023,
  author = {Hernandez, Soleil and Nguyen, Callistus and Parkes, Jeannette and Burger, Hester and Rhee, Dong Joo and Netherton, Tucker and Mumme, Raymond and Vega, Jean Gumma-De La and Duryea, Jack and Leone, Alexandrea and Paulino, Arnold C and Cardenas, Carlos and Howell, Rebecca and Fuentes, David and Pollard-Larkin, Julianne and Court, Laurence},
  title = {Automating the treatment planning process for 3D‐conformal pediatric craniospinal irradiation therapy},
  journal = {Pediatric Blood & Cancer},
  year = {2023},
  volume = {70},
  number = {3},
  doi = {10.1002/pbc.30164}
}
Kostenlos starten →