EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access · CC BY 4.0

Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis

Antonio Tufano, Davide Rosati, Martina Moriconi, Valerio Santarelli, Vittorio Canale iD, Stefano Salciccia iD, Alessandro Sciarra iD, Giorgio Franco, Vito Cantisani, Giovanni Battista Di Pierro iD

Current Oncology · 01.02.2024 · 31 (2) · 818-827

DOI: 10.3390/curroncol31020060 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Current Oncology, online erschienen am 01.02.2024. Verfasst von Antonio Tufano und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maternal-Infant and Urological Sciences, "Sapienza" Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy. Hauptthemen laut MEDLINE: Contrast Media, Urinary Bladder Neoplasms. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Contrast-enhanced ultrasound (CEUS) is a diagnostic tool that is gaining popularity for its ability to improve overall diagnostic accuracy in bladder cancer (BC) staging. Our aim is to determine the cumulative diagnostic performance of CEUS in predicting preoperative muscle invasiveness using a comprehensive systematic review and pooled meta-analysis.

Methods

A systematic review until October 2023 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Patients with BC suspicion were offered CEUS before the transurethral resection of the bladder tumor (TURBT). The diagnostic performance of CEUS was evaluated based on non-muscle-invasive bladder cancer (NMIBC) vs. muscle-invasive bladder cancer (MIBC) confirmed at the final histopathological examination after TURBT. The outcomes were determined through pooled sensitivity, specificity, pooled positive likelihood ratio (PLR+), negative likelihood ratio (PLR−), and area under the summary receiver operating characteristic (SROC) along with their respective 95% confidence intervals (CI).

Results

Overall, five studies were included. In these studies, a total of 362 patients underwent CEUS prior to TURBT. The pooled sensitivity and specificity were 0.88 (95% CI: 0.81–0.93) and 0.88 (95% CI: 0.82–0.92), respectively. SROC curve depicted a diagnostic accuracy of 0.94 (95% CI: 0.81–0.98). The pooled PLR+ and PLR− were 7.3 (95% CI: 4.8–11.2) and 0.14 (95% CI: 0.08–0.23), respectively.

Conclusions

Our meta-analysis indicates that CEUS is highly accurate in the diagnosis and staging for BC. Beyond its accuracy, CEUS offers the advantage of being a cost-effective, safe, and versatile imaging tool.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaUrinary Bladder NeoplasmsHumansMusclesSensitivity and SpecificityUltrasonography

Stichwörter der Autor:innen

accuracybladder cancercontrast-enhanced ultrasound (CEUS)meta-analysismuscle invasiveultrasound

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Maternal-Infant and Urological Sciences, "Sapienza" Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy.
  • Department of Radiology, Oncology and Pathology, University La Sapienza of Rome, 00185 Rome, Italy.

ORCID-Profile: Vittorio Canale, Stefano Salciccia, Alessandro Sciarra, Giovanni Battista Di Pierro

Zitieren

APA

Tufano, A., Rosati, D., Moriconi, M., Santarelli, V., Canale, V., Salciccia, S., Sciarra, A., Franco, G., Cantisani, V., & Di Pierro, G. B. (2024). Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis. Current Oncology, 31(2), 818-827. https://doi.org/10.3390/curroncol31020060

Vancouver

Tufano A, Rosati D, Moriconi M, Santarelli V, Canale V, Salciccia S, et al. Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis. Current Oncology. 2024;31(2):818-827. doi:10.3390/curroncol31020060

BibTeX
@article{Tufano2024,
  author = {Tufano, Antonio and Rosati, Davide and Moriconi, Martina and Santarelli, Valerio and Canale, Vittorio and Salciccia, Stefano and Sciarra, Alessandro and Franco, Giorgio and Cantisani, Vito and Di Pierro, Giovanni Battista},
  title = {Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis},
  journal = {Current Oncology},
  year = {2024},
  volume = {31},
  number = {2},
  pages = {818--827},
  doi = {10.3390/curroncol31020060}
}
Kostenlos starten →