Assessment of fitting methods and variability of IVIM parameters in muscles of the lumbar spine at rest
Frontiers in Musculoskeletal Disorders · 2024
DOI: 10.3389/fmscd.2024.1386276 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Musculoskeletal Disorders, 2024. Verfasst von Erin K Englund und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, United States. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, NIAMS NIH HHS, NICHD NIH HHS.
Abstract (Originalsprache)
Intravoxel incoherent motion (IVIM) MRI provides insight into tissue diffusion and perfusion. Here, estimates of perfusion fraction ( f ), pseudo-diffusion coefficient ( D *), and diffusion coefficient ( D ) obtained via different fitting methods are compared to ascertain (1) the optimal analysis strategy for muscles of the lumbar spine and (2) repeatability of IVIM parameters in skeletal muscle at rest. Diffusion-weighted images were acquired in the lumbar spine at rest in 15 healthy participants. Data were fit to the bi-exponential IVIM model to estimate f , D * and D using three variably segmented approaches based on non-linear least squares fitting, and a Bayesian fitting method. Assuming that perfusion and diffusion are temporally stable in skeletal muscle at rest, and spatially uniform within a spinal segment, the optimal analysis strategy was determined as the approach with the lowest temporal or spatial variation and smallest residual between measured and fit data. Inter-session repeatability of IVIM parameters was evaluated in a subset of 11 people. Finally, simulated IVIM signal at varying signal to noise ratio were evaluated to understand precision and bias. Experimental results showed that IVIM parameter values differed depending on the fitting method. A three-step non-linear least squares fitting approach, where D , f , and D * were estimated sequentially, generally yielded the lowest spatial and temporal variation. Solving all parameters simultaneously yielded the lowest residual between measured and fit data, however there was substantial spatial and temporal variability. Results obtained by Bayesian fitting had high spatial and temporal variability in addition to a large residual between measured and fit data. Simulations showed that all fitting methods can fit the IVIM data at signal to noise ratios >35, and that D * was the most challenging to accurately obtain. Overall, this study motivates use of a three-step non-linear least squares fitting strategy to quantify IVIM parameters in skeletal muscle.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, United States.
- Radiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States.
- Radiology, University of California, San Diego, La Jolla, CA, United States.
- Orthopaedic Surgery, Radiology, Bioengineering, University of California, San Diego, La Jolla, CA, United States.
Förderung
- NCATS NIH HHS
- NIAMS NIH HHS
- NICHD NIH HHS
Zitieren
APA
Englund, E. K., Berry, D. B., Behun, J. J., Frank, L. R., Ward, S. R., & Shahidi, B. (2024). Assessment of fitting methods and variability of IVIM parameters in muscles of the lumbar spine at rest. Frontiers in Musculoskeletal Disorders. https://doi.org/10.3389/fmscd.2024.1386276
Vancouver
Englund EK, Berry DB, Behun JJ, Frank LR, Ward SR, Shahidi B. Assessment of fitting methods and variability of IVIM parameters in muscles of the lumbar spine at rest. Frontiers in Musculoskeletal Disorders. 2024. doi:10.3389/fmscd.2024.1386276
BibTeX
@article{Englund2024,
author = {Englund, Erin K and Berry, David B and Behun, John J and Frank, Lawrence R and Ward, Samuel R and Shahidi, Bahar},
title = {Assessment of fitting methods and variability of IVIM parameters in muscles of the lumbar spine at rest},
journal = {Frontiers in Musculoskeletal Disorders},
year = {2024},
doi = {10.3389/fmscd.2024.1386276}
}
EUVIMED