Elastic modulus of cadaveric acetabular labrum correlates with ultrashort echo time (UTE) apparent spin-spin (T2*) and spin-lattice (T1) relaxation times
Frontiers in Musculoskeletal Disorders · 2024
DOI: 10.3389/fmscd.2024.1359296 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Musculoskeletal Disorders, 2024. Verfasst von Dina Moazamian und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of California San Diego, San Diego, CA 92093, USA. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAMS NIH HHS.
Abstract (Originalsprache)
Introduction
The acetabulum labrum plays a critical role in hip function. Medical imaging techniques for measuring changes in labral properties due to its degeneration may help improve our knowledge of its role in hip osteoarthritis (OA). This study aimed to explore the correlation between the mechanical properties of the acetabulum labrum and ultrashort echo time (UTE) MRI properties. Material and method Acetabular labrum specimens were dissected from 12 fresh-frozen human cadaveric hip joints (64.6 ± 11.6 years old at the time of death, 7 female). UTE Cones sequences were used to measure apparent spin-spin (T2*) and spin-lattice (T1) relaxation times using a knee coil at 3 T in a clinical MR scanner. The stiffness and the elastic modulus (E) of the specimens were measured before MRI scans using uniaxial tensile tests. Spearman's rank correlation coefficients of Tendons' UTE-T2* and -T1 with their mechanical properties were calculated.
Results
The human labrum specimen elastic modulus showed a significant inverse correlation with UTE-T2* ( R = −0.66, P < 0.01) and with UTE-T1 ( R = −0.56, P = 0.05). The stiffness of the specimens showed significant inverse correlations with UTE-T2* ( R = −0.53, P = 0.01) and UTE-T1 ( R = −0.63, P = 0.02).
Conclusion
This study highlighted the potential of UTE-MRI techniques for the mechanical assessment of the acetabular labrum. UTE-MRI may improve labrum degeneration detection and monitoring, which requires further investigations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of California San Diego, San Diego, CA 92093, USA.
- Department of Mechanical Engineering, Hiroshima University, JP.
- Department of Pathology, University of California San Diego, San Diego, CA 92093, USA.
- Shiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA 92037, USA.
Förderung
- NIAMS NIH HHS
Zitieren
APA
Moazamian, D., Hananouchi, T., Mohammadi, H. R. S., Hajian, S. A. T., Dorthe, E. W., D'Lima, D., Ma, Y., & Jerban, S. (2024). Elastic modulus of cadaveric acetabular labrum correlates with ultrashort echo time (UTE) apparent spin-spin (T2*) and spin-lattice (T1) relaxation times. Frontiers in Musculoskeletal Disorders. https://doi.org/10.3389/fmscd.2024.1359296
Vancouver
Moazamian D, Hananouchi T, Mohammadi HRS, Hajian SAT, Dorthe EW, D'Lima D, et al. Elastic modulus of cadaveric acetabular labrum correlates with ultrashort echo time (UTE) apparent spin-spin (T2*) and spin-lattice (T1) relaxation times. Frontiers in Musculoskeletal Disorders. 2024. doi:10.3389/fmscd.2024.1359296
BibTeX
@article{Moazamian2024,
author = {Moazamian, Dina and Hananouchi, Takehito and Mohammadi, Hamid Reza Shaterian and Hajian, Seyed Alireza Tayarani and Dorthe, Erik W and D'Lima, Darryl and Ma, Yajun and Jerban, Saeed},
title = {Elastic modulus of cadaveric acetabular labrum correlates with ultrashort echo time (UTE) apparent spin-spin (T2*) and spin-lattice (T1) relaxation times},
journal = {Frontiers in Musculoskeletal Disorders},
year = {2024},
doi = {10.3389/fmscd.2024.1359296}
}